Dexter Laundry 75LB CAPACITY COMPUTER CONTROL OPL WASHER Owner's Booklet

75lb capacity computer control opl washer

Advertisement

Quick Links

P/N 8514-081-001,
THE
DEXTER
COMPANY
WARNING - THIS WASHER IS EQUIPPED WITH DEVICES AND FEATURES RELATING TO ITS SAFE
OPERATION. TO AVOID INJURY OR ELECTRICAL SHOCK, DO NOT PERFORM ANY SERVICING
UNLESS QUALIFIED TO DO SO.
IT IS THE RESPONSIBILITY OF THE OWNER TO CHECK THIS EQUIPMENT ON A FREQUENT
BASIS TO ASSURE ITS SAFE OPERATION.
A machine should not be allowed to operate if any of the following occur:
- Excessively high water level.
- If machine is not connected to a properly grounded circuit.
- If the door does not remain securely locked during the entire cycle.
- Vibration or shaking from an inadequate mounting or foundation.
1. Always shut off power and water supply before servicing.
2. Do not overload the washer.
3. Do not open door when cylinder is in motion or it contains water.
4. Do not bypass any safety devices of this washer.
5. Do not use volatile or flammable substances in or near this washer.
6. Keep all panels in place. They protect against shock and injury and add rigidity to the washer.
DAILY
- Check that the loading door remains securely locked and cannot be opened during the entire cycle.
- Check the water connections for leaks.
- Clean the top and sides of the cabinet to remove residue.
- Clean the soap dispenser and lid.
- Check the drain valve for leaking and that it opens properly.
- Check the loading door for leaks. Clean the door seal of all foreign matter.
- Leave the loading door open to aerate the washer when not in use.
QUARTERLY
- Make sure the washer is inoperative by switching off the main power supply.
- Check the V-belts for wear and proper tension.
- Clean lint and other foreign matter from around motor.
- Check all water connections for leaks.
- Wipe and clean the inside of the washer and check that all electrical components are free of moisture and dust.
- Remove and clean water inlet hose filters. Replace if necessary.
- Check anchor bolts - retighten if necessary
IMPORTANT: Replace any and all panels that were removed to perform daily and/or quarterly maintenance.
OWNER'S BOOKLET
INSTALLATION & OPERATION
INSTRUCTIONS
Please read this information and retain for reference.
WARNING - FOR SAFETY
PREVENTIVE MAINTENANCE REQUIREMENTS
75LB CAPACITY
COMPUTER CONTROL
OPL WASHER

Advertisement

Table of Contents
loading

Summary of Contents for Dexter Laundry 75LB CAPACITY COMPUTER CONTROL OPL WASHER

  • Page 1 P/N 8514-081-001, 75LB CAPACITY COMPUTER CONTROL OPL WASHER DEXTER COMPANY OWNER'S BOOKLET INSTALLATION & OPERATION INSTRUCTIONS Please read this information and retain for reference. WARNING - THIS WASHER IS EQUIPPED WITH DEVICES AND FEATURES RELATING TO ITS SAFE OPERATION. TO AVOID INJURY OR ELECTRICAL SHOCK, DO NOT PERFORM ANY SERVICING UNLESS QUALIFIED TO DO SO.
  • Page 2: Installation Instructions

    DEXTER COMPANY INSTALLATION INSTRUCTIONS All washers must be installed in accordance with all local, state and national building, electrical, plumbing and other codes in effect in the area. WARNING - THESE INSTALLATION AND SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED PERSONNEL ONLY. TO AVOID INJURY...
  • Page 4 CONCRETE PEDESTAL MOUNTING FLOOR OUTLINE Figure 1-1 Figure 1-2...
  • Page 5: Fusing Requirements

    WARNING SHUT OFF POWER AND WATER BEFORE OPENING ANY SERVICE PANELS. Dexter single/three-phase 208-240VAC 60 Hz washing machines are intended to be permanently installed appliances. No power cord is provided. The machine should be connected to an individual branch circuit not shared by lighting or other equipment. The connection should be sheathed in liquid tight flexible conduit, or equivalent, with conductors of the proper size and insulation.
  • Page 6 The signals are not intended as a power source and must be limited to less than 100 milliamps of current. There is a separate terminal block for connection of the external injection signals. For the injection sources, program codes 0 through 6 are as shown in the table below. Dexter Controller Injection...
  • Page 7: Specifications

    SPECIFICATIONS MODEL 75LB WASHER CAPACITY 75LBS/11.5 CUBIC FT. (34.1 kg/325 l) CYLINDER SIZE 30” DIA X 28” DEEP (76cm X 71cm) ELECTRICAL 208-240 VAC, 60 HZ, 1 OR 3 PHASE DRIVE SYSTEM SOFT START REVERSING INVERTER DRIVE WASH SPEED 43 RPM INTERMEDIATE 412 RPM (60 G’S) EXTRACT...
  • Page 8: Starting The Washer

    STARTING THE WASHER A. Load the clothes into the cylinder and latch the door securely. Be sure clothing does not get caught between the door gasket and tub front when closing the door. Do not overload the washer. B. Select the appropriate cycle number (1 through 6) using for the load being washed. See the cycle descriptions in the programming section.
  • Page 9: Programming Instructions

    Programming can be accomplished manually using the machine controls or by connecting to the machine control using a PDA (personal digital assistant). For instructions on using a PDA with this washer control, please contact your local Dexter distributor. Please read below for manual programming instructions.
  • Page 10 Each bath can be programmed with the following options. Use the “DOWN” and “UP” keys to select the desired setting and the “START” key to move to the next option. DISPLAY FUNCTION OPTIONS Ct ** Tumble Time Two-digit amount of time in minutes. Water Temperature HH for hot, CH for warm, CC for cold and EE for no water.
  • Page 11 Cycle 1 Sheets & Pillowcases (Health Care) Bath Bath Cycle Water Water Delay Spin Injection Source Time Temp. Level Fill Time (min.) (min.) Flush Prewash Wash 1 (Detergent) Rinse 1 2 (Bleach) Rinse 2 Rinse 3 Rinse 4 Final 4 (Sour/Soft) Rinse Cycle 2 Towels / Pads / Diapers (Health Care)
  • Page 12 Cycle 3 White Towels (Hotel / Motel) Bath Bath Cycle Water Water Delay Spin Injection Source Time Temp. Level Fill Time (min.) (min.) Flush Prewash Wash 1 (Detergent) Rinse 1 Rinse 2 2 (Bleach) Rinse 3 Rinse 4 Final 4 (Sour/Soft) Rinse Cycle 4 Guest Laundry (Hotel / Motel or Health Care)
  • Page 13 Cycle 5 Rags & Mops (Hotel / Motel) Bath Bath Cycle Water Water Delay Spin Injection Source Time Temp. Level Fill Time (min.) (min.) Flush Prewash Wash Rinse 1 1 (Detergent) Rinse 2 Rinse 3 2 (Bleach) Rinse 4 Final Rinse Cycle 6 Colored Cotton Linen (Food &...
  • Page 14: Rapid Advance Mode

    There is a separate terminal block for connection of the external injection signals. For the injection sources, program codes 0 through 6 are as shown in the table below. See the ELECTRICAL section for more information. Dexter Controller Injection Recommended...
  • Page 15 Hose, Water Supply 8641-242-000 Washer, Inlet Hose 9565-003-001 Strainer, Inlet Hose INSTALLATION: (Available through Dexter Distributor): 9242-417-003 3” (76 mm) Flex Drain Hose, 10 ft. length (3 meters) Contact your distributor or The Dexter Company if a steel-mounting base is required.

This manual is also suitable for:

T-1200

Table of Contents