Dexter Laundry T-1800 Operators Manual Installation & Operation Instructions page 84

Commercial washers vended c-series control
Table of Contents

Advertisement

DRIVE_PHLI
DRIVE_PHLO
MOTOR_OL
8514-296-001 REV K page 84
Solution
VFD Input Phase
Condition
Loss
Delay
Action
Solution
VFD Output Phase
Condition
Error
Delay
Action
Solution
VFD Motor
Condition
Overheating
Delay
Action
Check VFD light code before turning off
power. Turn the power off to the washer.
Check the wiring connections to the S1,
S2, and +24V drive jumper connections.
If no problem is observed, turn on power
to the washer and test. If problem
reappears,
contact
representative.
This error occurs when an input phase
loss is detected
Occurs following the "DELAY" error (see
corresponding detail)
Stop the machine and clear the cycle.
Keep the door locked until the machine
has stopped moving and then unlock the
door.
Check VFD light code before turning off
power. Turn the power off to the washer.
Check the wiring connections to the drive
and motor.
If no problem is observed,
turn on power to the washer and test. If
problem reappears, contact your Dexter
representative.
This error occurs when an issue is
detected with the drive output phases
Occurs following the "DELAY" error (see
corresponding detail)
Stop the machine and clear the cycle.
Keep the door locked until the machine
has stopped moving and then unlock the
door.
Check VFD light code before turning off
power. Turn the power off to the washer.
Check the wiring connections to the drive
and motor.
If no problem is observed,
turn on power to the washer and test. If
problem reappears, contact your Dexter
representative.
This error occurs when the VF AC motor
drive is overheating
Occurs following the "DELAY" error (see
corresponding detail)
Stop the machine and clear the cycle.
Keep the door locked until the machine
has stopped moving and then unlock the
door.
your
Dexter