NEC NEAX 2000 IVS2 Maintenance Manual page 35

Integrated voice server
Hide thumbs Also See for NEAX 2000 IVS2:
Table of Contents

Advertisement

Table 1-9 Example of Fault Restoration Display Using MATWorX (Continued)
Fault
Alarm
Date
30
-
99/01/08 13:28
30
-
99/01/08 13:28
30
-
99/01/08 13:28
30
-
99/01/08 13:28
30
-
99/01/08 13:28
30
-
99/01/08 13:28
30
-
99/01/08 13:28
30
-
99/01/08 13:28
30
-
99/01/08 13:28
30
-
99/01/08 13:28
31
-
99/01/08 13:28
32
-
99/01/08 13:28
34
-
99/01/08 13:26
35
-
99/01/08 13:26
36
-
99/01/08 13:28
36
-
99/01/08 13:28
36
-
99/01/08 13:28
2
NEAX2000 IVS
Maintenance Manual
ND-70926 (E), Issue 3.0
CHAPTER 1 MAINTENANCE SERVICE FEATURES
CPU
AP 5
DTI line returned to normal condition
Multi frame loss
Data = (F2 FF FF FF FF FF FF FF)
AP 5
DTI line returned to normal condition
AIS error
Data = (F3 FF FF FF FF FF FF FF)
AP 5
DTI line returned to normal condition
Remote alarm
Data = (F4 FF FF FF FF FF FF FF)
AP 5
DTI line returned to normal condition
Multi Remote alarm
Data = (F5 FF FF FF FF FF FF FF)
AP 5
DTI line returned to normal condition
S-bit error
Data = (F6 FF FF FF FF FF FF FF)
AP 5
DTI line returned to normal condition
CRC error
Data = (F8 FF FF FF FF FF FF FF)
AP 5
DTI line returned to normal condition
Slip detected
Data = (F9 FF FF FF FF FF FF FF)
AP 5
DTI line returned to normal condition
Received signal is all ones (for BRT)
Data = (FA 01 FF FF FF FF FF FF)
AP 5
DTI line returned to normal condition
INFO 0
Data = (FB FF FF FF FF FF FF FF)
AP 5
DTI line returned to normal condition
INFO 2
Data = (FC FF FF FF FF FF FF FF)
AP 6
DCH/BRT/PRT D-Channel link connection returned to normal condition
(D-Ch NO. = 3)
Data = (03 FF FF FF FF FF FF FF)
AP 7
CCH/IPT link connection returned to normal condition
(CCH/IPT NO. = 3)
Data = (03 FF FF FF FF FF FF FF)
FP 0
Number of faulty trunks was less than predetermined number
Data = (FF FF FF FF FF FF FF FF)
MP
Number of lockout stations was less than predetermined number
Data = (FF FF FF FF FF FF FF FF)
FP1
DLC card returned to normal condition
Recover Kind No. : 0 (Station number = 200015)
Data = (00 00 80 20 00 15 FF FF)
FP1
DLC card returned to normal condition
Recover Kind No. : 2 (Station number = 200016)
Data = (02 00 80 20 00 16 FF FF)
FP1
DLC card returned to normal condition
Recover Kind No. : 3 (Station number = 200017)
Data = (03 00 80 20 00 17 FF FF)
Description
Fault Messages
Page 27

Advertisement

Table of Contents
loading

Table of Contents