Table 2-3 Remedial Action on Each Fault Kind (Continued)
FAULT
KIND
FAULT CONTENT
NUMBER
12
CS/ZT Fault
occurred
2
NEAX2000 IVS
Maintenance Manual
ND-70926 (E), Issue 3.0
FAULT INFORMATION
Fault Kind 05:
SYS-ID upload
failure
Fault Kind 06:
SYS-ID download
failure
CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
REMEDIAL ACTION
1
Check the LEN No. of the CS/
ZT with SYS-ID is correct by
CMAE YY=00>02
2
Make the CS/ZT Make busy
or Make idle condition by
CME5 Y=3.
3
Turn ON • OFF the CS/ZT
power switch.
1
When input the SYS-ID from
MAT, check if the number is
correct.
2
Check the CS/ZT is CS/ZT
without SYS-ID
3
Make the CS/ZT Make busy
or Make idle condition by
CME5 Y=3.
4
Turn ON • OFF the CS/ZT
power switch.