CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
Table 2-6 Remedial Action on Each Lamp Status (Continued)
CARD NAME
PN-BRTA
RUN lamp is not
(BRT)
flashing
ALM lamp is on
PN-2BRTC (BRT)
RUN lamp is not
flashing
ALM1 lamp is on
ALM0 lamp is on
Page 94
LAMP STATUS
Abnormal operation
of BRT card
Transmission line
fault
Abnormal operation
of BRT card
No. 1 circuit
transmission line
fault
No.0 circuit
transmission line
fault
FAULT
CONTENT
1
Confirm the programming data: CM05,
CM07 YY=02.
2
Check to see if the SENS switch is set
as per the AP Number (04-15)
assigned by CM05.
3
Reset the MB switch.
(Down→Up→Down)
4
If the fault cannot be cleared, replace
the card.
1
Confirm circuit line status.
2
Confirm PSTN line status.
1
Confirm the programming data: CM05.
2
Check to see if the SENS switch is set
as per the AP Number (04-15, 20-31)
assigned by CM05, CM07 Y=2.
3
Reset the MB switch.
(Down→Up→Down)
4
If the fault cannot be cleared, replace
the card.
1
Confirm No. 1 circuit line status.
2
Confirm PSTN line status.
1
Confirm No.0 circuit line status.
2
Confirm PSTN line status.
REMEDIAL ACTION
2
NEAX2000 IVS
Maintenance Manual
ND-70926 (E), Issue 3.0