CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
Table 2-6 Remedial Action on Each Lamp Status (Continued)
CARD NAME
PN-CFTC
RUN lamp is not on
(CFT)
PN-DAIA
RUN lamp is not
(DAIA)
flashing
LINK lamp is not on
RED lamp is on
RMT lamp is on
Page 98
LAMP STATUS
Abnormal operation
of CFT card
Abnormal operation
of DAIA card
Layer 2 link
connection failure
between DAIA and
DAIB
PCM signal loss or
Frame Alignment
signal loss
Remote alarm
FAULT
CONTENT
1
Confirm the programming data: CM05
Y=0/Y=1, CM07 YY=01.
2
Check to see if the SENSE switch is set
as per the AP Number (04-15, 20-31)
assigned by CM05 Y=0.
3
Reset the MB switch.
(Down→Up→Down)
4
If the fault cannot be cleared, replace
the card.
1
Reset the MB switch.
(Down→Up→Down)
2
Check the setting of SENSE switch.
1: FP No. 01
2: FP No. 02
3: FP No. 03
0, 4-F: Not used
3
If the fault cannot be cleared, replace
the card.
1
Check to see if the cable between DAIA
and DAIB is correctly connected.
2
Reset the MB switch.
(Down→Up→Down)
Check to see if the cable between DAIA and
DAIB is correctly connected.
Check to see if the cable between DAIA and
DAIB (sending side) is correctly connected.