: Fault Detail Kind
l
00: PCM loss
01: Frame loss
02: Multi-frame loss
03: AIS error
04: Remote alarm
05: Multi remote alarm
06: S-bit error
07: Not used
08: CRC error
09: Slip detected
0A: Received signal is all ones (for BRT)
0B: INFO 0 (for BRT)
0C: INFO 2 (for BRT)
0D: Not used
0E: Not used
0F: Not used
: D-Channel circuit No.
m
DCH/BRT/PRT: 00-07 =D-Channel No. 0-7
: CCH/IPT No.
n
00-07=CCH/IPT No. 0-7
: DLC Failure Kind
o
00: Terminal was cut off
02: Short circuit was made on the line
03: Ring wire was grounded
04: Tip wire was grounded or terminal was unconnected
05: Terminal failure
08: Terminal circuit failure
p
: LEN (000-763)
q
: Station No. (X-XXXXXXXX)
: DPC Failure Kind
r
00: DPC on the side of partner
01: DPC on the side of oneself
: DPC No.
s
2
NEAX2000 IVS
Maintenance Manual
ND-70926 (E), Issue 3.0
CHAPTER 1 MAINTENANCE SERVICE FEATURES