Component
COOKTOP
BURNER
BURNER
WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati
Fault
Description
Fan blocked
25
IPC
34
Heatsink NTC shorted
IPC
35
Heatsink NTC open
Coil1/2 NTC shorted
36
Coil1/2 NTC open or
37
1)
Visible check of the fun (some mechanical problem)
Check Fan connection – if the connector is plugged in
2)
well or not.
3)
Replace the Fan with a new one.
4)
If replacing the fan with a new one did not fix the
appliance, then the old fan is still good. Put it back in
the appliance. Change the IPC.
1)
Change the IPC;
1)
Change the IPC;
1)
Check if the NTC coil that is showing the failure is well
plugged in the proper connector.
2)
Replace the interested Coil with a new one.
3)
If replacing the Coil with a new one did not fix the
appliance, then the old coil is still good. Put it back in
the appliance. Change the IPC
1)
Verify if the room temperature is too low (<0°C)
Cold
2)
Check if the NTC coil that is showing the failure is well
plugged in the proper connector.
3)
Replace the interested Coil with a new one.
4)
If replacing the Coil with a new one did not fix the
appliance, then the old coil is still good. Put it back in
the appliance. Change the IPC
Service Action