SCE 2000 Configuration

There are four topology-related parameters:
Connection mode — Can be any one of the following, depending on the physical installation
of the SCE 2000 (Refer to Connection Mode Parameter (on page 3-9)):
Physically-connected-links — In cascaded configurations, this parameter defines the number
of the link connected to this SCE 2000 (Refer to Physically Connected Links Parameter (on
page 3-10)).
It is applicable only in a cascade topology.
Priority — This parameter defines which is the primary SCE 2000 (Refer to Priority (on
page 3-10)).
It is applicable only in a cascade topology.
On-failure — This parameter determines whether the system cuts the traffic or bypasses it
when the SCE 2000 either has failed or is booting. It is not applicable to receive-only
topologies (Refer to On-Failure Mode Parameter (on page 3-10)).
Any of these parameters may be configured via either the setup command or the
connection-mode command.

Connection Mode Parameter

The connection mode parameter refers directly to the physical topology in which the SCE 2000 is
installed. The connection mode depends on two factors:
Inline/Receive-only:
Cascade — Indicates a two SCE 2000 topology where the SCE 2000s are connected via the
cascade ports.
The connection mode parameter is determined by the physical deployment of the SCE 2000, as
follows:
Single SCE 2000 inline installation = "Inline" connection mode.
Single SCE 2000 external switch installation = "Receive-only" connection mode.
Two SCE 2000 inline installation = "Inline-cascade" connection mode.
Two SCE 2000 external switch installation = "Receive-only-cascade" connection mode.
OL-7826-05
Inline — single SCE 2000 inline
Receive-only — single SCE 2000 receive-only
Inline-cascade — two SCE 2000s inline
Receive-only-cascade — two SCE 2000s receive-only
Inline — The SCE 2000 resides on the data link between the subscriber side and the
network side, thus both receiving and transmitting packets.
Receive-only — The SCE 2000 does not reside physically on the data link. Data is
forwarded to the SCE 2000 via an external switch. The SCE 2000 itself receives only and
does not transmit.
Cisco SCE 2000 4/8xFE Installation and Configuration Guide