Rinnai 650FS Installation Manual page 17

Free standing gas fireplace
Table of Contents

Advertisement

8.
Fit ceiling plate to inside with appropriate fasteners (not supplied) in 4 places. Refer to diagram below.
Ceiling plate use is not mandatory as there is zero clearance requirement of dress tube to ceiling
material.
NOTE
9.
Continue flue lengths with B065411 650FS-PIPE1000 as required to B065412 650FSROOFCOWL. Finish off
as per illustration below.
The 139901 PC Tube Single Swage must enter the ceiling cavity I.
NOTE
10. Proceed to commissioning the engine.
Rinnai
B065412
650FSROOFCOWL
Minimum
Clearance
500mm
Flue pipe clip
supplied with
FS650KIT01
I
Decktite or lead collar
flushing (not supplied
Flue pipe clip
supplied with
FS650KIT01
B063960
Ceiling
Cover Plate
B063960
Single swage
PC Tube
17
FLUE INSTALLATION
B065411
650-FSPIPE 1000
650FS FIM