Omron Vision Sensor FH Series Connection Manual page 48

Robot abb corporation edition
Hide thumbs Also See for Vision Sensor FH Series:
Table of Contents

Advertisement

-1303
ERROR:fhrecvstring():RETRY:-1303
-1304
ERROR:fhrecvstring():TIMEOUT:-1304
-1502
ERROR:fhmeasureresult():PARAM_NUM:
-1502
-1601
ERROR:fhsample_trig():No Connection:
-1601
-1800
ERROR:fhmeasureresult():TRIG_NG:-1800
-1801
ERROR:fhmeasureresult():TJG_NG:-1801
 Precautions
The measurement result received from the Vision Sensor will be stored in param{*}. To
get the measurement result with this function, Result Output (Message) must be placed
in the flow, and the settings must be as follows
Result Output (Message) Processing Item
Setting Target
Output device
Termination string
Delimiter string
0
1
2
3
4
5
6
*1: The output data format should be set as follows
- Data type: Number
- Digits of integer: 6
- Digits of decimal: 4
Setting details
IoModule2: Serial (Ethernet)
∖r (Carriage Return)
∖x20 (Space)
Overall judgment (*1)
Robot command position X (*1)
Robot command position Y (*1)
Robot command position Z (*1)
Robot command position W (*1)
Robot command position P (*1)
Robot command position R (*1)
46
Receive retry count
overrun
Receive timeout time is
over.
Abnormal number of
parameters
Calling in the
unconnected state
Response NG
Overall judgment NG
The destination of the
received measurement
results
-
-
-
(Do not store)
param {1}
param {2}
param {3}
param {4}
param {5}
param {6}