66-047
IMI
DESK/WALL REVERSAL AND WALL MOUNTING
(22 Line/Feature Keyset and Single-Line Keyset, Only)
Conversion
To convert a station from a standard desk model to one which can be
hung on the wall, follow the procedure outlined below.
1 .
Remove and discard the pull out directory (22 Line/Feature
only).
2.
Remove the lower housing of the station, and rotate it 180
degrees.
The PWB contains circuitry which is sensitive to static
electricity discharge.
workplace are properly grounded to avoid any static
electricity discharge while performing the desk/wall
reversal.
3.
Remove the knockouts from the desired mounting holes as
illustrated in Figure 4-3.
4.
Replace the lower housing.
Wall Mounting
---- ---
Mount the station directly on the wall using two,
(obtained locally), or mount it on a wall jack cover plate.
1 .
Thread the #lo screws into the wall within l/8-inch of the
Refer to Figure 4-3 for the spacing dimensions.
surface.
2.
Insure that the housing is converted properly for a wall mounting
installation (see above instructions).
3.
Pull out the latching lever.
4.
Position the keyhole shaped holes in the bottom of the station
over the #lO screws or the cover plate studs.
down until a slight click is felt.
5.
Push the latching lever in to lock the station in place.
6.
To remove the station, pull out the latching lever, lift to unsnap
both screws or studs from the bottom housing, and lift the
away from the wall.
Be sure that your body and the
Make sure that all wires are clear.
4-7
Maintenance
Slide the station