IMI 66-047
Station Self Test
The multiline stations can be self tested for proper operation per the
following instructions.
Disconnect the line cord at the station base.
1.
THE ADJACENT ODD OK EVEN STATION WILL BE DISABLED DURING THE
TIME THAT THE STATION LINE CORD IS BEING DISCONNECTED OR
RECONNECTED.
2 .
Press and hold the
station connector.
test routine.
The sequence of the test is as follows:
SEQUENCE
1
B-Field indiactors light in turn and stay on
2
ITCM indicator lights
3
MONITOR indicator lights
4
All indicators extinguish in same order as lighted
5
Ringer sounds (be sure volume is set to med. or high)
SEQUENCE
1
MONITOR indicator lights
2
B-Field indicators light in turn and stay on
3
HOLD indicator lights
4
ITCM indicator lights
5
A-Field indicators light in turn and stay on
6
All indicators extinguish
7
Ringer sounds (be sure volume is set to med. or high)
3 .
Replace any station that does not pass the self test.
Test the DSS/BLF Console for proper lamp operation per the following
procedure.
1.
Disconnect the console line cord plug from the line.
Press and hold console key Cl0 while reconnecting the line cord
plug to the line.
IMPORTANT NOTE
MUTE
The station will automatically perform a Self
MUTE
Release the
3 AND 8 LINE KEYSET
INDICATION
22 LINE/FEATURE KEYSET
INDICATION
key as soon as the test begins.
4-3
Maintenance