Comdial ExecuTech 0616 Series User Manual

Model 0616x & 0816x electronic key systems

Advertisement

Quick Links

Model 0616X & 0816X
Electronic Key Systems
This manual applicable for the following key system models:
0616X Manufacturing Code 8xxC and Later
l
Codes
J

Advertisement

Table of Contents
loading

Summary of Contents for Comdial ExecuTech 0616 Series

  • Page 1 COMCHAL ExecuTech Model 0616X & 0816X Electronic Key Systems This manual applicable for the following key system models: 0616X Manufacturing Code 8xxC and Later * 0816X All Ma~uf&cturing Codes IMI 66-031.04 3/89...
  • Page 2: Table Of Contents

    Table of Contents IMI 66-031 TABLE OF CONTENTS CHAPl-ERt INTRODUCTION ......;‘: MANUAL SCOPE RELATEDPUBLICATioN’S .
  • Page 3: Regarding Fcc Rules And 'Regulations

    Replace the line cord or handset coiled cord. Replace complete stations and station handsets. The telephone operating company can temporarily dis- The handset is a special Comdial type. Other continue service and make changes which could effect handset types will not work properly.
  • Page 4 Introduction IM! 66-031 Operation of this equipment in a residential area may Disconnect all equipment not owned by the telephone cause interference to radio and television reception: in company. If this corrects the problem, the faulty equip- which case the user is encouraged to take whatever ment must not be reconnected to the telephone line until measures may be required to correct the interference.
  • Page 5: Chapter 2 Installation

    installation IMI 66-031 CHAPTER 2 INSTALLATION MOUNTING CONSIDERATIONS Afull scale mounting template is supplied in the packing box. Hold ortape it to the mounting sur- The KSU should be attached vertically to any stur- dy, flat, surface. It may be vertically rack mounted face, and mark the location of the mounting if desired.
  • Page 6: System Wiring

    IMI 66-031 Installation 19.22 INCHES l----sk~ - - - o - - Figure 2-1. Mounting DimenSlOnS SYSTEM WIRING A plug-in, powerline surge protectof should be System cabling may be routed concealed or visible as installed between the KSUpowercordand the installation location requires, Good engineering AC power eiectrkai outlet.
  • Page 7 The optional DSS/BLF console may be installed at any power failure. An industry standard, single-line station port to work in conjunction with a companion sta- telephone, such as a Comdial model 2500-xx, can be tion connected to the adjacent port (e.g.; port 10 for sta- connected to a power failure pair and used to provide tion and port 11 for console).
  • Page 8 IMl66-@31 Installation Wire the KSU TD (data to device from KSU) pin to Common Audtble and Auxiliary Station interface the device RD (receive data) pin. Two sets of relay closure drycontact points are avail- Wire the KSU SG (signal ground) pin to the device able at the J-l station connector block.
  • Page 9 Installation IMI 66-031 Area Paging Interface - Llne Port Paging - Station PA Port Area Interface A fine port can be configured by COS programming to A station port can be configured by class of service programming to be a PA port. As a PA port, it can be be an AUXILIARY port.
  • Page 10 Installation MI 66-031 CLIP TERM OUTPUT AS 24V@ 0.4A MAX REOUIRED BY VpOokZE RELAY COIL SUPPLY VOLTAGE CLAMPING DIODE RECOMMENDED v ;g :bXlNPUt SIGNALLING Flgure 2-2. External Signalling-Typical Connection. 600~ TO SOOn( 1:1) A SYSTEM A U D I O TRANSFORMi% TO KSU STATION INPUT...
  • Page 11 Installation IMI 66-031 Table 2-l. KSU To Station Wring. l .“m ---.I.- Y-L. ----.----a- STATION _-_. GREEN GREEN-WHITB YEUDW BLACK ers~mzu Is-.-- wmllt-JUIt VU&C “n==- V O I C E PAIR PAIR SLATE-WHITE 22 . Y E U O W 1 1 RED-BLUE DATA PAIR...
  • Page 13: Checkout

    Installation UNIT UNDtR 66Mxx BLOCK tH LtAD MEASURtD CHECKOUT CONNECTION POLARITY VOLTAGE TEST Check the KSU and telephone installation for proper Voice 1 TYPICAL EVEN operation by performing the following actions. Data 3 . +33+&5vDc STATlON (Repeat for Check voice 2 Resistance +33+1-SVDC each even sta.)
  • Page 14: Chapter3 System Programming

    IMI 66-031 System Programming CHAPTER 3 SYSTEM PROGRAMMING c&ate that the base level programming mode is GENERAL INFORMATION entered. Class Of Service (COS) programming consists of setting the Class Of Service (COS) operating con- Press *. The dial tone will return as a confirma- ditions.
  • Page 15 IMI 66-031 System Programming Al - A3 - A4 - A5 - A6 - - Ad3 0 El3 A7 - - Al4 - B6 - 87 B 5 - - 88 84 - 4’ Bl - - 83 - B2 Figure 3-l.
  • Page 16 IMl66-031 System Programming SYSTEM.COS PROGRAMMING PROCEDURE SYSTEM DEFAULTS All lines are DTMF Voice signalling attempted first when inter- com call is made 1 sec. pause time 2 sec. dial tone recall time 5. Select pulse dial operatlng characteristics. 30 sec. recall from hold Press 5.
  • Page 17 ~~166-031 If less than sixteen digits are entered on Press *. Dial tone will sound. line, select next entry location with toll restriction table entries. Refer to Select memory key. programming table (Table 3-4) to preselect entry Repeat procedure for each desired toll requirements.
  • Page 18: Line Cos Programming Procedure

    System Programming IMI 66-031 LINE COS PROGRAMMING PROCEDURE LINE DEFAULTS keys to assign toll restriction Press memory tables to Ilne. All lines private TABLE . TABLE All lines are CO lines No toll restriction Set Dialing mode is tone only msec.
  • Page 19: Stationcosprogramming Procedure

    IMI 66-031 System Programming STATION COS PROGRAMMING PROCEDURE Skip this step if PA port is not desired. STATION DEFAULTS Do not proceed beyond this step if PA r No ringing line preference enabled port selection is made. - No prime line is chosen 5.
  • Page 20 System Programming IMI 66-031 Is setected after trig features. If dtrect rtngtng 14. Set all-call and zone paglng capability. Default delayed rtngtng Is selected, delayed rtngtng wttt value is all-call at all stations in system. be disabled. Press 1. Tone burst sounds. Clears sta- tion from paging zones A, B, and C.
  • Page 21: Smdr And Cos Printout

    IMI 66-031 System Programming SMDR ANP COS PRINTOUT To obtain the COS printout, SMDR PRINTOUT A data printer can be connected to the system to be Press ITCM * 7 4 6 +% (base level if not active) used for printing station message detail recording (SMDR) information.
  • Page 22 STATION NUMBER MONTH/DAY/YEAR INITIATE TIME-HOUR : MINUTE (24 HOUR REAL TIME CLOCK) 4 0 C O L U M N P R I N T O U T LINES T [ C ! (LlNEj A R R I A G E R E T U R N X &ARRlAGE FE~URN DIALED DIGITS-UP TO MAXIMUM OF 32...
  • Page 23 System Programming IMi 66-031 TOLL RESTRICTION TABLES SYSTEM TABLE 1 PAUSE TIRE 2.0 SEC DENY PULSE DIAL 20 PPS FLASH TIME 720 MSEC HOLD RECALL 240 SEC LINE COS TABLE 2 ALLOW LINE PRV TYPE PU- HOLD TOLL 1 17034344664 LSE.SOMS TABLES 2 17039493113...
  • Page 24: Systemclockinformation

    System Programming IMI 66-031 SYSTEM CLOCK INFORMATION A clock date printing will automatically occur once SElTlNG THE CLOCK each 24-hour period. This daily, automatic printing will formatted as follows: 1 . Press ITCM, then dial +# #. 2 . Dial clock date with keypad keys. W MO/DY/YR 0O:OO (current date and 0O:OO hours) Values less than 10 must be dialed as P O W E R...
  • Page 25: System Speed Dial Programming

    System Programming IMI 66-031 SYSTEM SPEED DIAL PROGRAMMING To end procedure, Ten (10) system speed dial numbers can be stored from station 10 for use at all stations in the system. Press MONITOR To store speed dial numbers, SYSTEM SPEED DIAL INDEX Press ITCMt.
  • Page 26 IMI66-031 System Programming Table 3-l. System COS Programming Reference PROCEDURE RECORD (Shading Denotes Default Value) Note: Circle the record values at right Note: Circle the desired value before performing the procedure given below. for the system being programmed. 1. BASE LEVEL ENTRY PressfTCM*746+ 2 PULSWONE OR TONE ONLY D I A L I N G M O D E...
  • Page 27 1MI 66-031 System Programming 0. TOLL RESTRICTION RtQlhMtNTS Record all toll restricbn data on table 3-4. . Set system toll restriction requirements per instructions given on Table 3-4 9. SMDR DATA SPEED BAUD RATE . Press3=3oDbaud . Press OZlO baud .
  • Page 28 System Programming 66-031 Table 3-2. Line COS Programmlng Reference RECORD PROCEDURE (Shading Denotes System Default Values) NUlt NOlE Check each line number block for rhe fine featwu that is sd Enter the information In the box at right before Wrfte in the calling number and locaffon status. performing the pfugram pfucadwes givan below 1.
  • Page 29 IMI 66-031 System Programming Table 3-3. Statlon COS Programming Reference (Copy this sheet as required) PROCEDURE RECORD v&es st Circle or enter the record right before Enter lnfotmstion or circle desin?d veh8 below before INTERCOM NUMBER DlALTWO-DIGITPORT NUMBER . Press RECALL CONFIGUF&...
  • Page 30 System Programming IMI 66-031 Table 3-3, STATION COS PROGRAMMING REP ERENCE (Continued) (Copy this sheet as required) PROCEDURE circle or enter the record values at right 14. ALL CALLAND ZONE PAGING Press # lTCM to clear allcall. Press keys: Bl-B4 = receive A. B, C, and all-call Press keys: BS-B8 = originate A.
  • Page 31 Table 34. Toll RestrIctIon ProgrammIng Reference TABLE ENTRY PROCEDURE 6. Since it is important that emergency numbers never be restricted, always create an allow table Determine the types of dialing restrictions which wtth entriesof 911 and 1911 tooverride any DENY must be imposed on the system.
  • Page 32 System Programming 66-031 TOLL RESTRICTION TABLE 1 TYPE: ALLOW DENY ENTRY NUMBER (16 MAXIMUM) E N T R Y S T A T I O N S TABLE ASSIGNMENT: LINES TOLL RESTRICTION TABLE TOLL RESTRICTION TABLE 2 TYPE: ALLOW DENY TYPE: ALLOW DENY ENTRY NUMBER (16 MAXIMUM)
  • Page 33 EXECUTECH MODELS 0616X, 0816X CLASS OF SERVICE PROGRAMMING @J~@@~@lsksE LEVELI PROGAAtM NG KEY LAYOUT -SYSTEM OEFAULtr FUSE OR TON.5 ONLY SPECIFIES DIKINO WJDE CM KL L I N E S . @JUT K M mFAUT6 CLASS a SERYICE T O PRE-OElERUINEO CCttFIOU)ATION A S ESCAleEO IN E X T .
  • Page 34: Chapter 4 Maintenance

    If your KSU or an individual station needs repair, it EVEN STATION WILL BE DISABLED DURING may be returned to Comdial. Comdial will, at their op IHE TIME THAT THE STAnON UNE CORD IS tion, either repair the defective equipment or replace BEING DISCONNECTED OR RECONNECTED.
  • Page 35: Failure Analysis

    Maintenance IMI 66-031 Table 4-I. Station Pairing Press and hold the station 10 select key while reconnecting the line cord plug to the line. IMPORTANTNOTE: THE COMPANION STATtON WILL BE DISABLED DURING THE TIME THAT THE CONSOLEIS BEING DISCONNECTED AND RECONNECTED.
  • Page 36 FAILURE < PERFORM SELF TEST Fi%D TSLEPHONS INPUT FOR FAILED UNUSED TELCORSX JACK ON PSX REPLACE KSU AND PERFORM CO9...
  • Page 37 Index IMI 66-031 INDEX DsslBLF CONSOLE SELF TEST ... A-LEAD CONTROLDEVICE CONNECTlON ..... . AC POWER CONNECTION .
  • Page 38 Index 1Mf 66-031 ....SELF TEST, STATION- OVERLOAD PAIRING ....4 - 2 SMDRPRINTOUT .
  • Page 41 Placing a call ..... Answering a call....Placing a call on hold.
  • Page 42 On hook Press line key. Listen for dial tone. Dial number. 4if-t handset, when party answers. * Hang up handset to end call. Off hook Lift handset. Press line key. (This step is not necessary if a line has been assigned to you-a prime line.) Listen for dial tone.
  • Page 43 automatically ring at the station which placed it on hold after a programmed period of time. If the call is on exclusive hold, the call will revert to manual hold after the initial period. Voice signailing Lift handset. Press (m). Press a memory key (or dial extension number).
  • Page 44 If the line on which the call appears is shared by you and the station to receive the call Press(m). (Call is placed on hold automatically.) Press a memory key (or dial extension number). Voice announce the call and line number.
  • Page 45 Press line key for first call. Release both line keys. (Conference is established.) Add-on conference (1 external, 2 internal parties) Establish outside call. Press (m) (outside call placed on hold). Press a memory key (or dial extension number). Ask intercom party to lift his handset, and to press and hold down the held line key.
  • Page 46 Last number redial Press<#“e). (If on line, listening to shift dial tone, press key and then (..J Saved number redial (saving a number just dialed) Press(m), during or after the call. To,dial the saved number shift Press key and then(m) Automatic redial When busy tone is heard, press auto redial...
  • Page 47 Repeat the last four steps for each number to be stored. Press (w> to end programming. To automatically dial numbers Press memory key. When party answers, lift handset. To program numbers Follow same steps given for Automatic Dialing using the dial keys 1-O as memory locations, To speed dial numbers Press desired dial key 1-O.
  • Page 48 Repeat the last four steps for each number to be stored. Press c-3 to end programming. To dial numbers 8 l%s: ~?$$$f) then the dial key. (If on line, listening to dial tone, shift press key, (M’-band then the desired dial key 1-O.) To activate while on a call Press (WJ.
  • Page 49 One-button access (Paging unit connects to Key Service Unit line port.) Press line ,key dedicated to paging. Lift handset. (Dial area code if required.) Make announcement. Two-button access (Paging unit connects to Key Service Unit station port.) Press (m). Lift handset. Press a memory key (or dial 2-digit access code).
  • Page 50 Press (WI. Dial station number. Repeat last four steps for all stations. P r e s s - . Voice Signalling DSS Lift handset. Press memory key (l-l 4) Voice announce. If you are transferring a call, the Note: outside line is automatically placed on hold when a memory key is pressed.
  • Page 51 To prevent other party from hearing Press and hold down(m). Release (MUTE) to resume two-way conversation. If your telephone service is pulse (rotary) and you must convert to tone after selecting a line or while dialing Press<-3. (System will switch back to pulse dialing when call is terminated.) Note: PulselTone...
  • Page 52 Placing a call Press line key. i Dial number or press memory key. When party answers, speak toward the set. Answering a call Press line key. Speak toward the set. Ending a call Press (~@WQ. Switching from handset to speakerphone Press (W>.

This manual is also suitable for:

Executech 0816

Table of Contents