Parameter
Rise Time( no load )
Rise Time( full load
)
Fall Time( no load )
Fall Time( full load )
Transient Response
Time
Line Regulation
Load Regulation
Output protection
Remote Sense
Compensation
Voltage
External analog
(optional)
Load Mode
Rated value
Current
Voltage
Voltage
Voltage
Voltage
Voltage
Voltage
Current
Voltage
Current
OCP
OVP
Overpower
protection
current program
current monitor
voltage program
voltage monitor
Voltage
Current
Power
Resistance
Min. operating
voltage
Copyright © Itech Electronic Co., Ltd.
IT-M3901B-10-170
≤50ppm/℃
≤100ms
≤100ms
≤0.05% + 0.05%FS
≤0.05% + 0.05%FS
≤0.002%*I + 0.05%FS
≤0.05% + 0.05%FS
-125A or 175A
-1224W or 1734W
≤2V
External programming voltage -10V to 10V corre-
sponds to current -170A to 170A (effective range
-120A to 170A)
Current -170A to 170A corresponds to external
monitoring voltage -10V to 10V (effective range
-120A to 170A)
External programming voltage 0 to 10V Corre-
sponding voltage 0 to 10V
Voltage 0 to 10V corresponds to external monitor-
ing voltage 0 to 10V
3A~120A
12W~1200W
0.009Ω~3Ω
0.6V at 120A
Technical Specification
≤50ms
≤50ms
≤10ms
10.5V
0~10V
204