Current range: -720A~1020A
•
Power range: ±12kW
•
Bidirectional energy flow between the DUT and the grid, current seamless
switching
•
Master/slave parallel connection with patented technology - keep good per-
formance while power extension
•
Efficient power regeneration - reduce cost of electricity and cooling
•
CC/CV priority
•
Adjustable output impedance
•
Battery charge and discharge test
•
Battery simulation
•
Partial pre-compliant with LV123, LV148, DIN40839,ISO-16750-2,
SAEJ1113-11,LV124 and ISO21848 automotive testing standards *1
•
Slope of voltage, current and power is settable
•
Simulation of dynamic driving conditions, up to 10 million points
•
8 operation modes under Source mode:CC/CV/CW/CR/CC+CV/CV+CR/
CR+CC/CC+CV+CW+CR
•
Multiple protection: OVP / ±OCP / ±OPP / OTP /voltage transient drop pro-
tection/anti-islanding/power grid detection/pre-charge
•
Built-in USB/CAN/LAN/digital IO interfaces, Optional GPIB/Analog& RS232
*1 10V models don't have this function.
Voltage
Model
Level
IT-M3901B-10-170
IT-M3903B-10-340
10V
IT-M3905B-10-510
IT-M3910B-10-1020
IT-M3902B-32-80
IT-M3904B-32-160
32V
IT-M3906B-32-240
IT-M3912B-32-480
80V
IT-M3902B-80-40
Copyright © Itech Electronic Co., Ltd.
Power
Current
170A
1.7KW
340A
3.4KW
510A
5.1KW
1020A
10.2KW
80A
2KW
160A
4KW
240A
6KW
480A
12KW
40A
2KW
Quick Reference
Height
1U
1U
1U
2U
1U
1U
1U
2U
1U
2
Need help?
Do you have a question about the IT-M3900B Series and is the answer not in the manual?