Manitowoc Grove RT765E-2 Operator's Manual page 36

Hide thumbs Also See for Grove RT765E-2:
Table of Contents

Advertisement

SAFETY INFORMATION
Table 2-6 Example-Capacity Reduction Factors for Wind Speed V(z) Greater than 30 mph - Non-metric
(Only for lifting with main boom on fully extended outriggers, with or without stowed extension)
For wind speed Vz (3-second gust speed at boom tip height) is greater > 30> mph ≤ 45 mph, the Reduced Capacity
shall be calculated by multiplying the Published Rated Capacity by the following factors:
Wind Speed
Vz> 30 mph
< 45 mph
Factor
Wind resistance area of load, Awr
Maximum allowable wind resistance area in [ft
Wind resistance area of load, Awr
For wind resistance area of load, Awr
Manual.
Table 2-7 Awr Ratio and Permissible Wind Speed V(z) - Non-Metric
Note: Permissible and rated wind speeds in this table are the 3-second gust wind speeds at boom tip height.
Ratio:
For Rated Capacity@ 30 mph
For Allowable Capacity@ 45 mph
Example and Sample Calculations (Non-metric)
The following example illustrates how to calculate allowable
load while operating in wind speed (3-second wind gust
speed) above 13.4 m/s (30 mph) and maximum permissible
wind speeds with various combinations of lifted load and
wind resistance area.
NOTE:
Permissible and calculated wind speeds in this
example are the 3-second wind gust speeds at
boom tip height V(z).
Example 2:
A crane is configured with:
boom length = 90 ft,
load radius = 40 ft, and
wind speed is measured at V(z) ≤ 45 mph.
The Rated Load Chart Example - Non-metric (Figure 2-4),
at maximum permissible wind speed, V(z) = 30 mph, the
rated lifting capacity m
25,200 lb.
2-18
36
40
50
0.9
0.9
0.8
, shall not exceed maximum allowable wind resistance area Awr
(load)
= projected wind area Ap x wind drag coefficient Cd for the load.
(load)
> maximum allowable wind resistance, Awr
(load)
1.2
27.4
41.1
for this configuration is
(allow)
Published 4-09-2021, Control # 364-11
RT765E-2 OPERATOR MANUAL
Main Boom Length in Feet
60
70
80
0.8
0.8
0.8
2
],Awr
= 0.0059 x calculated reduced capacity in lb.
(allow)
1.4
1.6
Maximum Permissible Wind Speed (mph)
25.4
23.7
38.0
35.6
The maximum allowable wind resistance area of load is:
Awr
= 0.0059 x m
(allow)
Awr
= 0.0059 x 25,200 = 149 ft
(allow)
Lifting Limits at wind speed V(z) < 30 mph at this
configuration:
Maximum load 25,200 lb
Maximum wind resistance area of load 149 ft
For the allowable wind speed > 30 mph and ≤ 45 mph,
reduce the allowable load. , the Factor for a main boom
length of 90 ft is 0.8, thus the allowable load is:
m
= 0.8 x 25,200 = 20,160 lb
(allow)
This reduced capacity load has an allowable wind resistance
area of:
Awr
= 0.0059 x 20,160 = 119 ft
(allow)
L i f t i n g L i m i t s a t w i n d s p e e d V ( z ) > 3 0 m p h
and ≤ 45 mph at this configuration:
Maximum load 20,160 lb
Maximum wind resistance area of load 119 ft
90
100
110
0.8
0.7
0.5
(allow).
refer to crane Operator
(allow),
1.8
2
22.4
21.2
33.5
31.8
(2.5)
(load)
2
2
2
2