2.3.3 Settings menu.

Press the "Menu" button to access a list of variables that enable
you to customise use of the system.
To browse the menus, which can be accessed by pressing the rela-
tive "RH" or "LH" context buttons, scroll through the sub-menus
displayed by turning the main switch. Press the said selector to
select the one highlighted.
By pressing repeatedly, you can scroll down the menu levels and go
back to a previous level by pressing the "Indietro" (Back) context
button. To exit the menu completely, press the "Esci" (Exit) button,
which will take you back to the initial page of normal operation.
To confirm the parameter change, press the main switch.
ATTENTION.
By selecting the zone number equal to
1, the only zone present is identified as
Zone 1.
Voice menu
Set Point Zone 1
Defines the operating parameters to manage zone 1
Set Point Zone 2
Defines the operating parameters to manage the zone 2 (present with zone 2 optional kit)
DHW
Defines the operation parameters in domestic circuit mode
Time and Program
Defines the date/time and time operating slots
User
Defines the system parameters that can be modified by the user
Information
Display system operating data
Historical alarm code
Displays the list of the last 10 anomalies
Service
Password protected menu dedicated to a qualified technician
Language
Defines the remote panel operation language
Voice menu
Set comfort heat
Set economy heat
Set manual heat
Set flow heat
Offset flow heat
Set comfort cool
Set economy cool
Set manual cool
Set humidity cool
Set flow cool
Offset flow cool
Operating mode
44
Room temperature in central heating zone 1 Comfort mode
Room temperature in central heating zone 1 Economy mode
Room temperature in central heating zone 1 Manual mode
Flow temperature in room zone 1 central heating mode
Offset temperature for central heating zone 1
Room temperature in cooling zone 1 Comfort mode
Room temperature in cooling zone 1 Economy mode
Room temperature in cooling zone 1 Manual mode
Humidity value set for zone 1 in cooling mode
Flow temperature in room zone 1 cooling mode
Offset temperature for cooling zone 1
Zone 1 operating mode
The following menus refer to firmware rev. 1.0.
Set Point Zone 1
DHW
Time and Program
Info
Historical alarm code
Esc
Hereunder is a list of available menus
MAIN MENU
Description
Set Point Zone 1 Menu
Description
Menu
[ ... ]
[ ... ]
[ ... ]
[ ... ]
[ ... ]
Back
Personalized
Range
Default
15 - 35 °C
20
5 - 25 °C
16
5 - 35 °C
20
20 ÷ 85 °C
25
- 15 - + 15°C
0
15 - 35 °C
25
15 - 35 °C
28
15 - 35 °C
25
30 - 70 %
50
5 - 25 C
20
-15 - + 15 °C
0
AUTO-
AUTO
MAN-OFF
43
value