1.11 TRIO PACK REMOTE PANEL.

1.12 REMOTE PANEL INSTALLATION
OPERATIONS.
1) Separate the fixing template from the body of the remote panel
using a screwdriver as a lever in the relative recess (Fig. 19).
Install the remote panel away from heat sources and in a suitable
position to detect the room temperature correctly.
2) Install the remote panel using the openings on its rear part
directly onto the wall or on a recess box using the relative
supplied screws.
3) Connect the remote panel to the electronic management
clamps, as indicated in the diagram (Fig. 20).
The connection is made using wires with a minimum section
of 0.50 mm
and maximum section of 1.5 mm
2
maximum length of 50 metres.
N.B: for correct installation, prepare
a dedicated line to connect the remote
control according to the Standards in
force regarding electrical systems. If this is not
possible, interference due to other electric ca-
bles could cause malfunctioning of the remote
control itself.
4) Fix the body of the remote control to the mount template,
engaging it with pressure.
5) After the pack has been powered, wait about 30 seconds before
regulation so that communication between remote panel and
the pack has established.

1.13 ELECTRICAL CONNECTION.

The Trio Pack Hybrid device has protection rating IPX5D. Elec-
trical safety of the appliance is reached only when it is correctly
connected to an efficient earthing system as specified by current
safety standards.
ATTENTION.
and with a
2
The manufacturer declines any respon-
sibility for damage or physical injury
caused by failure to connect the Trio Pack
Hybrid device to an efficient earthing system or
failure to comply with the reference standards.
Also ensure that the electrical system corresponds to max-
imum absorbed power specifications as shown on the
Trio Pack Hybrid data nameplate.
The pack is supplied complete with an "X" type power supply
cable without plug.