2.6
PARAMETERS AND INFORMATION
MENU
Pressing the "MENU" button (2), the display cyclically shows the
"Data" menu, "User" menu and a menu protected by a "0000" ac-
cess code with the first flashing digit reserved for a qualified tech-
nician.
To access an individual menu, once it appears, press the "OK" but-
ton (1).
Data Menu.
Parameter ID
D 03
Storage tank unit temperature
D 04
Value calculated for system setting
D 05
Value set for DHW setting
Outdoor temperature (if the outdoor unit external probe is connected or if the optional external
D 06
probe is available)
D 08
System return water temperature
D 09
List of the last five anomalies (to scroll the list press "OK" (1)).
D 10
Anomaly list reset. Once "D 10" is displayed, press "OK".
D 14
Circulator pump flow rate
D 20
System flow temperature
D 22
DHW 3-way (DHW = domestic hot water, CH = central heating)
D 24
Chiller circuit liquid temperature
D 25
Zone 2 flow temperature (if configured)
D 26
Probe for primary solar storage (puffer)
D 28
System circulator pump instantaneous speed
D 31
DHW integration function
D 32
System integration function
D 34
Heat pump disabling
D 35
Solar system inlet
D 36
Not Used
D 41
Relative humidity zone 1 (if zone 1 humidity sensor active)
D 42
Relative humidity zone 2 (if zone 2 humidity sensor active)
D 43
Zone 1 humidistat (if zone 1 humidistat active)
D 44
Zone 2 humidistat (if zone 2 humidistat active)
D 45
Dehumidifier zone 1
D 46
Dehumidifier zone 2
D 47
Zone 1 circulator pump
D 48
Zone 2 circulator pump
D 49
Central heating / cooling system separation 3-way (CL = cooling, HT = heating)
D 51
Zone 1 remote panel
D 52
Zone 2 remote panel
D 53
System setting with remote connection in zone 1
D 54
System setting with remote connection in zone 2
D 55
Zone 1 thermostat
To scroll through the menu items and to edit the values, use the
heating temperature control buttons (5). Pressing the "OK" but-
ton (1) confirms the parameter, while pressing the "ESC" button
(3) goes back to the previous menu or exits.
A minute after the last operation, the system automatically exits
any of the menus.
The menus of the control panel, found in the booklet, re-
fer to rev. 3.0 of the P.C.B. firmware.
Description
Range
-10 ÷ 130 °C
5 ÷ 65 °C
10 ÷ 65 °C
- 20 ÷ 50 °C
-10 ÷ 130 °C
-
-
0 ÷ 9999
-10 ÷ 130 °C
DHW- CH
-10 ÷ 130 °C
-10 ÷ 130 °C
-10 ÷ 130 °C
0 ÷ 100 %
OFF - ON
OFF - ON
OFF - ON
OFF - ON
-
0 ÷ 99 %
0 ÷ 99 %
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
CL - HT
OFF - ON
OFF - ON
5 ÷ 65 °C
5 ÷ 65 °C
OFF - ON
39