1.28 MAIN COMPONENTS KIT.

Key (Fig. 36):
1
- Storage tank draining cock / tap
2
- Sacrificial anode
3
- Antifreeze thermostat
4
- 8 bar safety valve
5
- Antifreeze kit connection box
6
- Storage tank flange
7
- Domestic hot water vessel Shut-off cock
8
- Manifold draining valves
9
- One-way valve
10 - System flow-meter
11 - 3 bar safety valve
12 - System circulator pump
2
16
15
9
14
13
12
11
10
9
8
7
6
5
4
3
2
1
13 - Filling cock / tap
14 - Manual air vent valve
15 - DHW probe
16 - Storage tank / Cylinder
17 - Management electronics
18 - Boiler
19 - Automatic air vent valve
20 - 3-way valve (motorised)
21 - Heat pump flow probe
22 - Hydraulic manifold
23 - System probe
24 - Chiller line connection gaseous status
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
25 - Plate heat exchanger
26 - Liquid phase detection probe
27 - Heat pump return probe
28 - Chiller line connection liquid status
29 - Direct zone pump
30 - 8 l domestic hot water expansion vessel
31 - Direct zone
flow temperature thermometer
32 - Gas Cock