INFORMATION MENU

Pressing the "MENU" button (2), the display cyclically shows the
"Data" menu, "User" menu and a menu protected by a "0000" ac-
cess code with the first flashing digit reserved for a qualified tech-
nician.
To access an individual menu, once it appears, press the "OK" but-
ton (1).
Data Menu.
Parameter ID
D003
Storage tank unit temperature
D004
Value calculated for system setting
D005
Value set for DHW setting
Outdoor temperature (if the condensing unit external probe is connected or if the optional exter-
D006
nal probe is available)
D008
System return water temperature
D009
List of the last five anomalies (to scroll the list press "OK" (1)).
D010
Anomaly list reset. Once "D 10" is displayed, press "OK".
D014
Circulator pump flow rate
D020
System flow temperature
D022
DHW 3-way (DHW = domestic hot water, CH = central heating)
D024
Chiller circuit liquid temperature
D025
Zone 2 flow temperature (if configured)
D026
Probe for primary solar storage (puffer)
D028
System circulator pump instantaneous speed
D031
DHW integration function
D032
System integration function
D034
Heat pump disabling
D035
Solar system inlet
D036
Not Used
D041
Relative humidity zone 1 (if zone 1 humidity sensor active)
D042
Relative humidity zone 2 (if zone 2 humidity sensor active)
D043
Zone 1 humidistat (if zone 1 humidistat active)
D044
Zone 2 humidistat (if zone 2 humidistat active)
D045
Dehumidifier zone 1
D046
Dehumidifier zone 2
D047
Zone 1 circulator pump
D048
Zone 2 circulator pump
D049
Central heating / cooling system separation 3-way (CL = cooling, HT = heating)
D051
Zone 1 remote panel
D052
Zone 2 remote panel
D053
System setting with remote connection in zone 1
D054
System setting with remote connection in zone 2
D055
Zone 1 thermostat
D056
Zone 2 thermostat
System model definition ( MP = Magis Pro V2; MCI = Magis Combo V2; MCP = Magis Combo
D061
Plus V2)
D062
Communication with condensing unit interface board
To scroll through the menu items and to edit the values, use the
heating temperature control buttons (5). Pressing the "OK" but-
ton (1) confirms the parameter, while pressing the "ESC" button
(3) goes back to the previous menu or exits.
A minute after the last operation, the system automatically exits
any of the menus.
Description
Range
-10 ÷ 130 °C
5 ÷ 65 °C
10 ÷ 65 °C
- 20 ÷ 50 °C
-10 ÷ 130 °C
-
-
0 ÷ 9999
-10 ÷ 130 °C
DHW- CH
-10 ÷ 130 °C
-10 ÷ 130 °C
-10 ÷ 130 °C
0 ÷ 100 %
OFF - ON
OFF - ON
OFF - ON
OFF - ON
-
0 ÷ 99 %
0 ÷ 99 %
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
CL - HT
OFF - ON
OFF - ON
5 ÷ 65 °C
5 ÷ 65 °C
OFF - ON
OFF - ON
MP - MCI - MCP
OFF - ON
37