Table 5-18
POST error messages (continued)
Screen message
1203—Game Port Address
Conflict Detected
1720 SMART Hard Drive
Detect Imminent Failure
1780—Disk 0 Failure
1781—Disk 1 Failure
1782—Disk Controller Failure
1785—Multibay incorrectly
installed
1790—Disk 0 Error
1791—Disk 1 Error
ENWW
Probable cause
Device IRQ address conflicts with
another device.
Hard drive is about to fail. (Some hard
drives have a firmware patch that will
fix an erroneous error message.)
The drive is not installed correctly or
has failed.
The drive is not installed correctly or
has failed.
Hard drive circuitry error.
No other IDE device may be attached
to the same IDE controller.
The drive is not installed correctly or
has failed.
The drive is not installed correctly or
has failed.
Recommended action
Reset the IRQ
1.
Determine if hard drive is giving correct error
message.
2.
Run the Drive Protection System test if applicable.
3.
Apply firmware patch if applicable
(see http://www.hp.com/support).
4.
Back up contents and replace hard drive.
1.
Be sure that any jumpers are set correctly, and
that power and drive cables are connected, both
to the drive and the system board.
2.
Verify that the cables are the correct cables for
your computer model. If this message persists,
you might need service for your workstation.
1.
Be sure that any jumpers are set correctly and that
power and drive cables are connected, both to the
drive and the system board.
2.
Verify that the cables are the correct cables for
your computer model. If this message persists,
you may need service for your workstation.
1.
Run Computer Setup (F10 Setup).
2.
Clear CMOS.
3.
Verify cable seating/jumper settings.
4.
Run hard drive diagnostics.
5.
Disconnect additional drives.
6.
Run the Drive Protection System test if available.
7.
Replace the hard drive.
8.
Replace the system board.
Attach the MultiBay as device 0 on the secondary IDE
controller.
1.
Be sure that any jumpers are set correctly and that
power and drive cables are connected, both to the
drive and the system board.
2.
Verify that the cables are the correct cables for
your computer model. If this message persists,
you may need service for your workstation.
1.
Be sure that any jumpers are set correctly and that
power and drive cables are connected, both to the
drive and the system board.
2.
Verify that the cables are the correct cables for
your computer model. If this message persists,
you may need service for your workstation
POST and error messages
139