TECHNICAL SPECIFICATIONS FOR OUTDOOR UNIT
Model Number
Product Code Number
Rated Voltage & Frequency and Phase
Min./ Max. Operating Voltage
Circuit Breaker Size (A)
Working Temperature Range (° F)
Refrigerant (R410A), (oz.)
Min. Circuit Ampacity (A)
Low Ambient Cooling Function
Sound Power Level dB(A) (Max.)
Capacity Invert Range (Btu/h)
Cooling
Capacity Invert Range (Btu/h)
Heating
Fan Motor
Outdoor Fan
Air Flow Volume of Outdoor Unit (CFM)
Compressor
Condenser
Coil Length x Height x Width (in)
Unit Dimensions (W x H x D) (in)
Dimensions &
Packing Dimensions (W x H x D) (in)
Weight
Connection
(between outdoor and indoor unit) (ft)
(between indoor and indoor unit) (ft)
Charge over Design Length [*4] (oz. / ft)
*1. Using a 3/8" to 1/4" adaptor joint when connect this port to a 9K, 12K,18K or 24K wall mounted indoor unit.
*2. Using a 1/2" to 3/8" adaptor joint when connect this port to a 9K or 12K (SHE12H4ZIGB only) wall mounted indoor unit.
*3. Using a 5/8" to 3/8" adaptor joint when connect this port to a 9K indoor unit. Or, using a 5/8" to 1/2" adaptor joint when
connects this port to a 18K / 12K (SHE12H4ZIGX only) wall mounted indoor unit.
NOTE: For other types of indoor unit connection, please refer to the specification for connecting size.
*4. When the total length of liquid line is over 164 ft, the additional refrigerant charge is required.
*5. When the outdoor unit is above the indoor unit, the maximum vertical height should not exceed 49.2 ft.
NOTE: Outdoor unit must connect to a minimum of TWO indoor units.
950-0203-revK
Rated Capacity (Btu/h)
Rated Power Input (W)
Total Input Current (Cooling)
SEER
Rated Capacity (Btu/h)
Rated Power Input (W)
Total Input Current (Heating)
HSPF
Fan Type
Output (W)
Capacitor (UFD)
Fan Motor RLA (A)
Fan Speed (RPM)
Fan Blade Diameter (in)
Model
TYPE
Brand
RLA
Input (W)
Crankcase Heater Input (W)
Oil Type
Overload Protector
Number of Rows
Fin spacing (in)
Fin Type
Tube Outside Dia.(in)
Number of circuits
Defrosting Method
Net / Gross Weight (lb)
Flare Liquid line
Flare Suction line
Service Port Fitting
High Pressure (psi)
Low Pressure (psi)
Design Length (ft)
Max Line Set Vertical Height
Max Line Set Vertical Height
Max Line Set Length (ft)
Max Line Set Length (ft)
Wiring (Indoor to Outdoor)
SMZ42H46ZOGX
243-1007-C
208-230 / 1PH
187 / 253 VAC
50
Cooling: 14 to 118; Heating: 5 to 81
169.3
29
Yes
68
40,000
8,530 - 46,403
4,400
21.6 / 19.5 A
16
44,500
10,662 - 47,768
4,600
22.5 / 20.5 A
8.2
Axial Fan
140
6
1.1
860
22.44
3237
TNB306FPGMC
Inverter Scroll
MITSUBISHI
21.5
3010
40
PVE
CS01F272H01
2
0.055
Aluminum, Louvered
0.313
40.25 x 41.57 x 1.5
5
Automatic Defrosting
39.96 x 43.43 x 17.32
45.59 x 48.62 x 19.41
224.9 / 246.9
Four of 1/4 " - 9K, 12K, 18K BTU;
One of 3/8" - 21K / 24K BTU [*1]
Two of 3/8"-9K BTU;
Two of 1/2"-12K / 18K BTU [*2];
One of 5/8"-21K / 24K BTU [*3]
1/2" - 20 UNF
550
240
24.6 (for each indoor unit) (123' total)
49
24.6
82 (for each indoor unit)
262.5 (total)
0.24 (over 164')
4C- 14 AWG (Recommended)
- 22 -