Sea Breeze SMZ42H46ZOGX Installation Manual page 11

Mini-split five port multi zone
Table of Contents

Advertisement

Mounting the Outdoor (condenser) Unit
Follow the clearance guidelines in the diagram
above. Clearance distances are minimums.
Minimum clearance above unit is 12" to allow for
servicing.
Install drain plug as in Figure 9 (included). Drain
hose not included.
Do not mount this unit close to combustibles or
heat sources.
Although this unit is fairly quiet when in operation,
do not mount this unit where noise issues could be
a problem.
Mount unit on an equipment pad or solid surface, install drain plug and tube as necessary. If wall mounting is
necessary a wall mount bracket may be purchased (BR-440L) for this purpose. Follow mounting instructions for
bracket to ensure safe installation.
Anchor bolts of the proper size and type (Installer provided) must be used.
For best results mount this unit as close as possible to the evaporators. Check maximum line length below
before mounting.
Maximum Line length and height
Connection Length
L1 + L2 + L3 + L4 + L5
Lx
H1
H2
MAXIMUM LINE LENGTH AND / OR HEIGHT MUST NOT BE EXCEEDED!
950-0203-revK
Outdoorunit
Equivalent length of the farthest fitting pipe Lx
L1
L2
a
Indoor unit
Indoor unit
Total Length
Max. Length for any indoor unit
Max. Height between each indoor and the outdoor unit.
Max. Height difference between indoor units.
L3
L4
b
c
d
Figure 10
Description
- 11 -
Figure 9
L5
e
Max. Length
262.5 feet.
82 feet.
49 feet
24.6 feet
March 1, 2016