Parts Included With Indoor Unit; Installer Supplied Parts; Condensate Pump - Sea Breeze SMZ42H46ZOGX Installation Manual

Mini-split five port multi zone
Table of Contents

Advertisement

Wall-mounted Indoor unit
Wall Bracket
Remote Control
Batteries for Remote Control (2 AAA)
Remote Control Holder
Adapter:
1/2"F to 3/8"M (9510198) with 9K indoor and/or
12K unit.
3/8"F to 1/2"M (9510197) with 18K and/or 12K
indoor unit(s).
Operation Manual
 Drain Tubing 6 ft.
Note: The outdoor unit can be connected to different types of indoor unit as followings:
Console: 9K - SMZC9H4ZIGX; 12K - SMZC12H4ZIGX, 18K - SMZC18H4ZIGX.
Cassette: 12K - SMZCA12H4ZIGX, 18K - SMZCA18H4ZIGX, 24K – SMZCA24H4ZIGX
Floor / Ceiling: 9K - SMZFC9H4ZIGX; 12K - SMZFC12H4ZIGX, 18K - SMZFC18H4ZIGX,
24K – SMZFC24H4ZIGX.
Ducted: 9K - SMZD9H4ZIGX; 12K - SMZD12H4ZIGX, 18K - SMZD18H4ZIG, 21K – SMZD21H4ZIG,
24K – SMZD24H4ZIG.
For the detail information about the included parts and connecting for above indoor units, please refer to the
manual to be included with each indoor unit.
The following additional Items are required for proper installation.
Refrigerant line set: Insulated copper tubing:
9K Indoor – 1/4" (liquid line) and 3/8" (suction line).
o
12K Indoor –1/4" (liquid line) and 1/2" (suction line) for SHE12H4ZIGX;
o
18K Indoor – 1/4" (liquid line) and 1/2" (suction line).
o
24K Indoor – 1/4" (liquid line) and 5/8" (suction line).
o
Flare nuts 2 ea. required per line, see above (line set) for size.
Vinyl UV resistant tape.
Supply Power:
o
50 amp circuit breaker
Interconnect wire cable:
o
4C 14 AWG stranded (Recommended)/ 4C 16 AWG stranded (minimum) per indoor unit.
Refrigerant - R410A required for additional line set charge.
Sealing putty.
1/4" to 5/16" access fitting adaptor (PN: QC-S5)
Mounting hardware - Wall anchors, condenser pad etc.
Surge protector (highly recommended)
VERY IMPORTANT: Condensate pump P/N 4100130 can not be powered from the indoor unit. Power
connections must be made at outdoor unit supply power.
Main system breaker or disconnect sized per unit requirements should be mounted adjacent to outdoor unit.
950-0203-revK
PARTS INCLUDED WITH UNIT

INSTALLER SUPPLIED PARTS

1/4" (liquid line) and 3/8" (suction line) for SHE12H4ZIGB
Outdoor Unit
Drain Fitting
Installation Manual
Terminal Label
Adapter:
1/4"F to 3/8"M (951-0251) – 2 pcs,
1/2"F to 3/8"M (951-0252) – 2 pcs,
1/2"F to 5/8"M (951-0253) – 2 pcs
3/8"F to 1/4"M (951-0254),
5/8"F to 3/8"M (951-0255),
3/8"F to 1/2"M (951-0256),
5/8"F to 1/2"M (951-0257)
- 4 -
March 1, 2016