Installation Steps; Notes To Installer - Sea Breeze SMZ42H46ZOGX Installation Manual

Mini-split five port multi zone
Table of Contents

Advertisement

Installation Steps:

Select the location for the indoor and outdoor unit. (page 7)
Mount the indoor wall brackets. (page 8)
Drill wall penetration holes. (page 8)
Hang the indoor units. (page 9)
Locate and mount the outdoor unit. (page 10)
Connect and route line set. (page 11 – 13)
Connect the wiring from the indoor unit to the outdoor unit. (Page 14 – 17)
Evacuate line set. (page 18)
Test system. (page 20)
Operational Test
This manual is to aid the qualified HVAC contractor in the installation of this Mini Split system.
Report all shipping damage to the carrier IMMEDIATELY. Check units and box exterior for damage.
Please read and understand these instructions prior to installing the unit, failure to comply with these
instructions may result in improper installation, operation and maintenance, possibly resulting in fire, electrical
shock, property damage, personal injury or death.
CAUTION! Do not use old refrigerant lines with new installation:
For connecting pipes use new and clean piping materials with high pressure fittings made for R410A only. This
air conditioner adopts the new HFC refrigerant (R410A) which does not destroy ozone layer. R410A refrigerant
operates at approximately 1.6 times the pressure of refrigerant R22. Accompanied with the adoption of the new
refrigerant, the refrigeration lubricating oil has also been changed. During installation be sure that water, dust or
foreign material does not enter into the new system. The system must not be left open to the atmosphere for
any reason for any period of time as the systems oil quickly absorbs moisture and will contaminate and
damage the system. To prevent mixing of refrigerant or refrigeration lubricating oil, the sizes of connecting
sections of charging port on main unit and installation tools are different from those used for the conventional
refrigerant units. Accordingly, special tools are required for the new refrigerant (R410A) units. The best and
recommended solution is - do not use the existing line sets because there may be some problems with
pressure fittings and possible impurities in the existing piping.
When installing this unit, an electrical surge suppressor is recommended.
Installers please pass this manual and warranty registration to end user. If technical assistance is required
during installation or start up, please call 704-504-8590 (M-F 8:00 am to 4:30 pm ET) to speak to a Technical
Service Engineer. Before calling please have the Model and Serial numbers available.
Safety Instructions:
1. Carefully read all instructions prior to installation.
2. Check Rating Plate for correct system voltage before installing the unit. Installing and operating a
unit with the incorrect voltage may result in malfunction or other issues and will void the warranty.
3.
Units must be connected to a correctly grounded electrical supply.
4.
Do not use the units if they have been dropped or otherwise damaged or installed incorrectly.
The manufacturer of the unit will not be liable for any damages caused by failure to comply with the installation
and operating instructions in this manual.
The unit rating plate contains pertinent information for unit operation; please refer to it as required.
Inspect all parts for damage prior to installation and start up. Units must be installed by a qualified HVAC
contractor.
950-0203-revK

NOTES TO INSTALLER

- 3 -
March 1, 2016

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents