Outdoor unit Installation

Connect Refrigeration Lines to Bundled Lines from Indoor Unit
Use standard A/C practices to attach the connection pipes to the proper pipes of the bundled lines coming
through the wall from the indoor unit.
Tighten the flare nut of the connection pipes using a spanner and torque
wrench. (see diagram)
Note: Do not over-tighten flare nuts, or the connection may be damaged.
Insulate/Bundle Refrigeration Lines and Wiring
Individually insulate all refrigeration lines and condensation drainage hose to
ensure that they do not sweat. This will help to maintain the unit at its proper capacities.
Once all lines have been properly insulated, bundle the refrigeration lines with the wiring conduit and wrap
securely to complete the run to the outdoor unit.
Note: The condensation drainage hose should be left free of the bundled lines in order to drain properly.
Install Outdoor Condensation Drainage Hose (Heat Pump Models only)
When the heat pump unit is heating or defrosting, wastewater forms in
the outdoor unit. This can be drained off using the outdoor drain elbow
and hose provided.
Insert the drain elbow into the hole on the base plate as shown.
Join the drain hose to the elbow and turn so that the water drains to the
desired location.
- -