Select Locations For Indoor Unit; Select Locations For Outdoor Unit; Line Set Length - Sea Breeze SMZ42H46ZOGX Installation Manual

Mini-split five port multi zone
Table of Contents

Advertisement

Selecting locations for the Indoor unit (Wall-mounted)
1. Determine the best location for mounting the
Indoor unit. Ensure the dimensions
requirement indicated be the arrows are
followed.
2.
Paying close attention to the air circulation in
the room, these units throw air approximately
15ft. Ensure that no obstacles impede airflow.
3. Do not mount this unit close to a heat source
or a doorway.
Note:For the detail information about other
types of indoor units, please refer to the manual
to be included with each indoor unit.
Selecting location for Outdoor unit
1. Determine the best location for mounting the
outdoor unit. Ensure the dimensions
requirement indicated be the arrows are
followed.
2. Do not mount this unit close to combustibles
or heat sources.
3. Although this unit is fairly quiet when in
operation, do not mount where noise issues
could be a problem.

Line set length

Locate the Indoor and Outdoor units as close together as possible. Line set height cannot exceed
specifications.
Installation Notes:
1. The maximum total line set length must not exceed 262.5 feet for all units.
2. SMZ42H46ZOGX is designed to operate two to five indoor units. DO NOT use this system with one indoor
unit.
3. This unit max design length is 123 ft. for the each indoor units. The maximum total line set length for all
units is 262.5 ft. Refrigerant must be added (0.24 oz/ft.) when line set total length exceeds 123 ft. for all
units.
NOTE: An oil trap is recommended if the indoor unit is over 15 feet in height from the outdoor unit.
950-0203-revK
Space to the ceiling
6"
Above
6" Above
Space to the wall
120"
Above
Air outlet side
- 7 -
Space to the wall
6" Above
78"
Above
Space to the floor