Outdoor Unit (Condenser) Installation - Sea Breeze SMZ18H46ZOGX Installation Manual

High efficiency series mini-split dual / triple / quad zone
Table of Contents

Advertisement

The location must allow easy servicing and provide good air circulation as shown in the illustration below:
12" or above
Space to the wall
Mounting the Outdoor (condenser) Unit
Follow the clearance guidelines in the
diagram above. Clearance distances
are minimums. Minimum clearance
above unit is 12" to allow for servicing.
Install drain plug as in Figure 7a
(included). Drain hose not included.
Do not mount this unit close to
combustibles or heat sources.
Although this unit is fairly quiet when
in operation, do not mount this unit
where noise issues could be a problem.
Mount unit on an equipment pad or solid surface, install drain plug and tube as necessary. If wall mounting is
necessary a wall mount bracket may be purchased (BR-440L) for this purpose. Follow mounting instructions for
bracket to ensure safe installation.
Anchor bolts of the proper size and type (Installer provided) must be used.
For best results mount this unit as close as possible to the evaporators. Check maximum line length
specifications before mounting.
MAXIMUM LINE LENGTH AND / OR HEIGHT MUST NOT BE EXCEEDED!
950-0195revJ

OUTDOOR UNIT (CONDENSER) INSTALLATION

79" or above
(Air outlet side)
12" or above
(Air inlet side)
Figure 7
- 10 -
20" or above
Figure 7a
December 3, 2015