Error Codes - GLP impression X5 User Manual

Hide thumbs Also See for impression X5:
Table of Contents

Advertisement

www.glp.de

7. Error codes

The impression X5's self-diagnosis system can display the following error codes:
Code
HEAT
MEMER
FANER
NETER
VERER
36
DMX control modes overview
Comment
Overtemperature condition
detected. Fixture will be
powered off and cooldown
sequence will be initiated.
Communication with onboard
flash memory not possible, or
written data in flash memory
cannot be read properly
(inability to read flash data can
be due to end of flash memory
lifetime)
Fan error
Network engine error
Version error – mismatch of one
or more driver version
numbers from the expected
packet version numbers
impresssion X5 User Manual
Action
Disconnect fixture from power.
Find reason for overheating and
rectify.
Disconnect fixture from power.
Discuss issue with GLP Support.
Disconnect fixture from power.
Find reason for fan error and
rectify. If necessary, discuss issue
with GLP Support.
Disconnect fixture from power.
Discuss issue with GLP Support.
Disconnect fixture from power.
Check currently available
firmware for fixture. Discuss issue
with GLP Support.

Advertisement

Table of Contents
loading

Table of Contents