Filling Flow; Exhaust Time - Festo MS6 SV E 10V24 Series Operating Instructions Manual

Soft start/quick exhaust valve
Table of Contents

Advertisement

Technical data
12.5

Filling flow

Flow rate qn dependent on the number of rotations n of the flow control screw
Fig. 19: Flow diagram
12.6

Exhaust time

The following table shows the exhaust time in normal operation (N) and in the event of a fault (F) for
different volumes and operating pressures.
NOTICE
In the case of a fault (F) the worst possible fault in the valve's interior is assumed (worst case).
Normal operation: N
Fault case: F
Volume [l]
2
N
(F)
10
N
(F)
20
N
(F)
40
N
(F)
150 N
(F)
Tab. 13: Exhaust time
30
Operating pressure
3.5 bar
Exhaust time [s]
to 1.0 bar
to 0.5 bar
0.1
0.2
(0.16)
(0.22)
0.3
0.45
(0.4)
(0.6)
0.5
0.85
(0.8)
(1.25)
1.2
1.9
(1.7)
(2.8)
3.2
5.0
(4.8)
(8.2)
p1 = 10 bar
p1 = 8 bar
p1 = 6 bar
p1 = 4 bar
Operating pressure
6 bar
Exhaust time [s]
to 1.0 bar
to 0.5 bar
0.24
0.3
(0.28)
(0.35)
0.55
0.7
(0.8)
(1.1)
1.0
1.3
(1.5)
(2.2)
2.2
3.0
(3.4)
(5.3)
6.0
8.2
(9.8)
(15.4)
Festo — MS6(N)-SV-...-E-10V24 — 2021-11e
Operating pressure
10 bar
Exhaust time [s]
to 1.0 bar
to 0.5 bar
0.3
0.4
(0.36)
(0.52)
0.7
0.9
(1.2)
(1.9)
1.4
1.7
(2.4)
(3.9)
3.0
3.9
(5.1)
(8.1)
11.0
12.8
(16.2)
(29.0)