Product overview
Fig. 6: Connection with NECA-...-MP3
– static enable signals with opposite potentials
– Time delay of the level change of the enable signals is monitored
– Behaviour on detection of a cross circuit:
– Product in exhausted status: remains in safe status and switches to malfunction
– Product in pressurised status: switches to safe status and to malfunction
Fig. 7: Static enable signals – signal distance
Switching characteristics diagrams è Fig. 23.
MS6-SV-E with multi-pin plug socket NECA-S1G9-P9-MP5
NOTICE
A cross circuit between the enable signals EN1/EN2 is not detected and does not cause an error
response. The system is pressurised only if the enable signals are applied correctly.
• Ensure that detection of shorts across contacts is established and guaranteed by corresponding
measures in the peripherals (PLC/safety control) in accordance with the valid safety standards.