Technical data
Runtime performance of enable signals
t1 > 5 ms:
Level of EN2 (EN1) must be HIGH (LOW) for min. 5 ms (debounce time/input
filter/stabilisation time).
t2 < = 75 ms:
maximum permissible delay time between EN1 and EN2.
Exceeding maximum permissible delay time:
– Product is not pressurised and an error message is output (NECA-...-MP3)
– Product is not pressurised and an error message is output (NECA-...-MP5)
t3 > = 15 ms:
Level of EN2 (EN1) must be LOW (HIGH) for min. 15 ms (debounce time/input
filter/stabilisation time).
t4 = 2 ms:
maximum internal time delay caused by the program sequence.
Pressurisation > 300 ms
tp1 } 2:
Exhausting > 2 s
tp2 } 3:
Tab. 15: Runtime performance of enable signals