Electrical Installation - Festo MS6 SV E 10V24 Series Operating Instructions Manual

Soft start/quick exhaust valve
Table of Contents

Advertisement

Installation
– Use only suitable silencers è www.festo.com/catalogue.
– Screw the silencer into pneumatic port 3.
– Make sure exhaust has no obstacles: do not block silencer or port 3.
6.2

Electrical installation

WARNING
Risk of injury due to electric shock.
• For the electric power supply, use only PELV circuits that ensure a reliable electric disconnection
from the mains network.
• Observe IEC 60204-1/EN 60204-1.
Connecting earthing strap
Connect the pre-assembled earth strap to the earth potential with low impedance (short cable
with large cross-section).
This prevents malfunctions due to electromagnetic interference and ensures electromagnetic compati-
bility in accordance with the EMC Directives.
Fig. 16: Earth cable connection
Connecting multi-pin plug socket NECA
The product may only be used with the approved NECA multi-pin plug sockets NECA-....
Information on terminal connections can be found in the assembly instructions enclosed with the
multi-pin plug socket.
20
Festo — MS6(N)-SV-...-E-10V24 — 2021-11e