Advertisement

Table 3-1 Remedial Action on Each Lamp Status (Continued)
CARD NAME
LAMP STATUS
PN-DAIF
RUN lamp is not
(DAIF)
flashing.
LINK lamp is not on. Layer 2 link connec-
RMT lamp is on.
PN-DAIF
PWR lamp is on.
(DAIF)
2
NEAX2000 IVS
Remote PIM System Manual
ND-70917 (E), Issue 1.0
FAULT CONTENT
Abnormal operation
of DAIF card
tion failure between
DAID and DAIE
Remote alarm
PCM signal loss
CHAPTER 3 TROUBLESHOOTING
REMEDIAL ACTION
1 Reset the MB switch.
(Down→Up→Down)
2 If the fault cannot be
cleared, replace the card.
1 Check to see if the cable
between DAID and DAIE is
correctly connected. Refer
to
"Connection Between
Main Site and Remote Site"
on Page
47.
2 Reset the MB switch.
(Down→Up→Down)
3 Check whether cable
between DAIF cards is
correctly connected. Refer
to
"Connection Between
Main Site and Remote Site"
on Page 47.
Check to see if the cable
between DAIF cards (sending
side) is correctly connected.
Refer to
"Connection Between
Main Site and Remote Site" on
Page 47.
Check to see if the cable
between DAID and DAIE is
correctly connected. Refer to
"Connection Between Main
Site and Remote Site" on Page
47.