Log Messages; The Vb-C50Fsi/Vb-C50Fi Log Messages - Canon VB-C50FSi User Manual

Fixed poe network camera
Hide thumbs Also See for VB-C50FSi:
Table of Contents

Advertisement

Log Messages

The VB-C50FSi/VB-C50Fi Log Messages

The Syslog log messages are classified into the following 5 categories. Classification details are
dealt with in the UNIX syslog.
Classification
crit
err
warning
notice
info
■ Camera Server-related Log Messages
●A001 Camera server startup failure (crit)
Message
%1
Explanation
Response
●A002 Protocol initialization failure (err)
Message
%1
Explanation
Response
●A007 View restriction setting error (warning)
Message
Explanation
Response
7-4
Fault Severity
Level
Error
Critical fault at the software level (stops task operation)
Fault involving a malfunction (operation interrupted)
Error
Fault not involving malfunction
Warning
Warning
Fault outside the system
Information on correct operation
Information
no %1 installed
sources | protocols
Capture and initialization of protocols has failed, and the camera server
has failed to start.
If rebooting does not solve this problem, there is a malfunction. Contact an
authorized Canon service representative.
%1 protocol not installed
Protocol type (LS/C | LS/D | LS/H)
Initialization of WebView has failed. The setting information may be corrupted.
Correct the settings or return to factory-shipped settings.
inconsistent view restriction for camera[1]
The view restriction settings are corrupted. The camera control functions
on the affected camera cannot be used.
Restore the factory default settings or reset the view restrictions.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vb-c50fi

Table of Contents