Terminal Block Settings; Terminal Block 22 - E7 - N; Terminal Block 23 - E8 - N; Terminal Block 24 - E9 - N - Abexo 051D User Manual

230 vac multifunction control unit
Table of Contents

Advertisement

E7
Terminal block 22 is associated with a normally closed (N.C.) contact. The parameters that can be set are:
n
DISABLED,
Ac
LIMIT SWITCH CLOSING MOTOR A. This control unit is supplied with the standard setting where terminal block
= n). When a NORMALLY CLOSED contact is connected to terminal block 22, it is automatically detected by
22 is disabled
(E7
the control unit that sets the parameter of the terminal block to the correct safety fuction, in this case
CLOSING MOTOR A. This feature is called AUTO-ENABLE.
E8
Terminal block 23 is associated with a normally closed (N.C.) contact. The parameters that can be set are:
n
DISABLED,
ob
LIMIT SWITCH OPENING MOTOR B. This control unit is supplied with the standard setting where terminal block
23 is disabled
= n). When a NORMALLY CLOSED contact is connected to terminal block 23, it is automatically detected by
(E8
the control unit that sets the parameter of the terminal block to the correct safety fuction, in this case
OPENING MOTOR B. This feature is called AUTO-ENABLE.
E9
Terminal block 24 is associated with a normally closed (N.C.) contact. The parameters that can be set are:
n
ob
DISABLED,
LIMIT SWITCH OPENING MOTOR B. This control unit is supplied with the standard setting where terminal block
24 is disabled
(E9
= n). When a NORMALLY CLOSED contact is connected to terminal block 24, it is automatically detected by
the control unit that sets the parameter of the terminal block to the correct safety fuction, in this case
OPENING MOTOR B. This feature is called AUTO-ENABLE.
The standard setting of inputs is negative common
E1 N.O.
n
n
DISABLED
Go
Go
START
PE
PEDESTRIAN
PE
oP
OPEN
oP
cL
cL
CLOSE
Po
OPEN DEAD MAN
Po
Pc
CLOSE DEAD MAN
Pc
EL
ELECTRIC LOCK
EL
E6 N.C.
n
n
DISABLED
Ao
(*) LIMIT SWITCH
AC
OPENING
MOTOR A
STANDARD TERMINAL BLOCKS CONFIGURATION OR WHEN RESTORED TO FACTORY SETTINGS
* N.C. inputs are disabled, as standard configuration:
When the inputs are connected, the control unit automatically sets them to the correct safety function.

TERMINAL BLOCK SETTINGS

TERMINAL BLOCK 22 - E7 - NORMALLY CLOSED
TERMINAL BLOCK 23 - E8 - NORMALLY CLOSED
TERMINAL BLOCK 24 - E9 - NORMALLY CLOSED
=
E0
02
E2 N.O.
E3 N.C.
n
DISABLED
DISABLED
ST
START
(*) STOP
PEDESTRIAN
OPEN
CLOSE
OPEN DEAD MAN
CLOSE DEAD MAN
ELECTRIC LOCK
E7 N.C.
E8 N.C.
n
DISABLED
DISABLED
(*) LIMIT SWITCH
ob
(*) LIMIT SWITCH
CLOSING
OPENING
MOTOR A
MOTOR B
=
E3
. To set the inputs with positive common, change to
E4 N.C.
n
DISABLED
tc
(*) CLOSING
PHOTOCELL
MODE 1
td
CLOSING
PHOTOCELL
MODE 2
E9 N.C.
n
DISABLED
ob
(*) LIMIT SWITCH
OPENING
MOTOR B
=
=
=
=
.
E4
E5
E6
E7
n
9
USER MANUAL - 230 VAC MULTIFUNCTION CONTROL UNIT - 051D
E7
E8
E9
=
E0
E5 N.C.
n
DISABLED
ta
(*) OPENING
PHOTOCELL
tc
CLOSING
PHOTOCELL
MODE 1
N.O. = NORMALLY OPEN
N.C. = NORMALLY CLOSED
=
Ac
LIMIT SWITCH
ob
=
LIMIT SWITCH
=
ob
LIMIT SWITCH
.
01

Advertisement

Table of Contents
loading

Table of Contents