230 vac multifunction control unit
Table of Contents

Advertisement

pe
PEDESTRIAN
op
OPEN
CL
CLOSE
EL
ELECTRIC LOCK
do
ACTIVATE OUTPUT
AUTOMATIC
PROGRAMMING
9p
ERROR
LIMIT SWITCH MOTOR
A + LIMIT SWITCH
ab
MOTOR B
OPENING LIMIT
ao
SWITCH MOTOR A
CLOSING LIMIT
ac
SWITCH MOTOR A
OPENING LIMIT
o2
SWITCH MOTOR B
CLOSING LIMIT
oc
SWITCH MOTOR B
--
STAND BY
OPERATIONAL REPORTS AND PRIORITIES
The PEDESTRIAN function can open and close door A of the gate
F1
for the time
programmed. Its operation also depends on the
programming of the parameters made (
F6
= multiple residents mode - see "GENERAL FUNCTIONS") and
on the status of the other inputs.
The OPEN function always starts the gate by opening depending
on the status of the photocells, stop and limit switches.
The CLOSE function always starts the gate by closing depending
on the status of the photocells, stop and limit switches.
The ELECTRIC LOCK function activates the electric lock
for 3 seconds. The parameter
L0
00
L0
01
ues
=
or
=
The ACTIVATE OUTPUT function starts the function connected to
the programmable outputs
must be connected to the correct source (see PROGRAMMABLE
OUTPUTS).
This error is reported after automatic programming of SENSOR
p6
9P
. Error
indicates that one or more parameters related to
the obstacle sensor have not been calibrated.
To check which parameters are not programmed, check the value
p6
of the following parameters
URATION MOTOR A/B"). The parameters set to
programmed.
The function LIMIT SWITCH MOTOR A when opening or closing is
active at the same time as the function LIMIT SWITCH MOTOR B
when opening or closing.
If the gate is fully closed and both closing limit switches (motor A
and motor B) are installed, the display will show
priority of other events.
The function OPENING LIMIT SWITCH OF MOTOR A is active: it
ends the stroke of motor A when opening.
The function CLOSING LIMIT SWITCH OF MOTOR A ends the
stroke of motor A when closing.
The function OPENING LIMIT SWITCH OF MOTOR B is active: it
ends the stroke of motor B when opening.
The function CLOSING LIMIT SWITCH OF MOTOR B ends the
stroke of motor B when closing.
No function is active, no event is detected
USER MANUAL - 230 VAC MULTIFUNCTION CONTROL UNIT - 051D
F5
= step-by-step mode /
L0
must be set to the following val-
.
o1
o2
and
. The output functions
p7
b7
b8
,
,
and
(see "CONFIG-
n
have not been
ab
subject to the
15
e1
e2
r3
9
10
e1
e2
r6
9
10
e1
e2
r6
9
10
r6
r6
e6
e7
22
23
e8
e9
24
25
e6
22
e7
23
e8
24
e9
25
r7
r7
r7
r7