Motor A Settings; Standard Time; Slowdown Time; Soft Start (Achieving Set Torque) - Abexo 051D User Manual

230 vac multifunction control unit
Table of Contents

Advertisement

Motor A can be configured using 8 parameters identified by the letter a.
Forces and thresholds are expressed in decimals and correspond to %. Ex:

STANDARD TIME

a1

SLOWDOWN TIME

a2

SOFT START (ACHIEVING SET TORQUE)

a3
WAITING TIME BEFORE CLOSING
a4
A1
STANDARD TIME
Motor A works for
A1
seconds at force A5. At the end of this time, motor A slows down. This occurs during both opening and closing.
Motor A opens before motor B. Motor A closes after
A2
SLOWDOWN TIME
A2
seconds at force A6. The slowdown phase is performed after the normal working time for both opening and clo-
Motor A works for
sing. To disable the slowdown of motor A, set the parameter
P2
will be carried out without considering the slowdown phase of motor A.
A3
SOFT START (ACHIEVING SET TORQUE)
When starting, motor A gradually increases the force until it reaches the set force A5. During this time the obstacle detection sensor is
disabled.
A4
DELAY AT CLOSING (MOTOR A)
At the end of the opening phase and after the automatic closing time F0, motor B starts the closing phase. After
also begins to close. This time is useful to avoid overlapping of the doors during the closing phase.

TORQUE ADJUSTMENT/STANDARD FORCE

A5
During STANDARD TIME
A1
10%. The force of the motor increases or decreases the sensitivity of the obstacle sensor: the greater the force set, the lower the sensitivity;
the lower the force set, the higher the sensitivity.
A6
TORQUE ADJUSTMENT/STANDARD FORCE
During SLOWDOWN TIME
A2
of 10%. The force of the motor increases or decreases the sensitivity of the obstacle sensor. The greater the force set, the lower the sensiti-
vity. The lower the force, the greater the sensitivity.
A7
STANDARD OBSTACLE
If the force of motor A detected is greater than the STANDARD OBSTACLE THRESHOLD
unit detects an obstacle. If the force of motor A detected is greater than the set threshold, the gate reverses the movement if it is the first
detection in the working cycle, otherwise it goes to the limit switch.
Once the obstacle is detected, the gate performs a safety procedure by moving one door at a time.
In order to facilitate calibration of the STANDARD OBSTACLE THRESHOLD, the control unit's display during opening shows the force of
motor A as a number from
SLOWDOWN OBSTACLE THRESHOLD
A8
During the SLOWDOWN TIME
CLE THRESHOLD
A8
set. Obstacle detection during slowdown acts as a limit switch. In order to facilitate calibration during OPENING, the
display of the control unit shows the force of motor A as a number from
the (+) KEY until the display does not show n.

MOTOR A SETTINGS

sec = seconds
Times are expressed in seconds
14 sec
7 sec
0,8 sec
6 sec
a4
the force of motor A is
A5
the force of motor A is
a6
00
to 99. To disable obstacle detection press the (+) KEY until the display shows n.
a2
the control unit detects an obstacle if the force of the motor is greater than the SLOWDOWN OBSTA-
% = percentage parameter
STANDARD FORCE (from 10% to 100%)
a5
SLOWDOWN FORCE (from 10% to 100%)
a6
STANDARD OBSTACLE DETECTION THRESHOLD
a7
SLOWDOWN OBSTACLE DETECTION THRESHOLD
a7
MINIMUM:
seconds with respect to motor B.
MINIMUM:
A2
0. 0
=
sec. Setting the slowdown to zero also means that programming
MINIMUM:
MINIMUM:
MINIMUM:
01
% of the total. The force of motor A can be set from 10% to 100% in steps of
MINIMUM:
01
% of the total. The SLOWDOWN FORCE can be set from 10% to 100% in steps
MINIMUM:
00
MINIMUM:
00
00
to 99. To disable obstacle detection during slowdown press
16
USER MANUAL - 230 VAC MULTIFUNCTION CONTROL UNIT - 051D
n = disabled
01
= 10%
0. 0
sec
MAXIMUM:
0. 0
sec
MAXIMUM:
0. 1
sec
MAXIMUM:
0. 0
sec
MAXIMUM:
= 10%
MAXIMUM:
= 10%
MAXIMUM:
= 0%
MAXIMUM:
a7
set, during STANDARD TIME
= 0%
MAXIMUM:
8/10 %
10/10 %
n %
n %
99
sec
99
sec
1. 5
sec
B1+B2
sec
A4
seconds, motor A
10
= 100%
10
= 100%
n
= disabled
a1
the control
n
= disabled

Advertisement

Table of Contents
loading