Function Overview; Auto-Close Time; Pedestrian Time; Kick Back Function At Closing - Abexo 051D User Manual

230 vac multifunction control unit
Table of Contents

Advertisement

There are many functions that allow the operation of the gate to be customised. These are identified within the menu by the letters
sec = seconds
Forces and thresholds are expressed in decimals and correspond to %. Ex:

AUTO-CLOSE TIME

f0

PEDESTRIAN TIME

f1

KICK BACK FUNCTION AT CLOSING

f2

PRE-BLINKING TIME

f3

KICK BACK FUNCTION AT OPENING

f4

STEP-BY-STEP MODE

f5
MULTIPLE RESIDENTS MODE
f6
FAST CLOSURE
f7
f0
AUTO-CLOSE TIME
After opening, the gate remains fully open for
CLOSE TIME keep the (+) KEY pressed down for a long time, until the display shows
open after opening has finished.
f1
PEDESTRIAN TIME
In the event that the gate is started by a PEDESTRIAN order,
med during the opening phase, but will be performed during the closing phase. During a PEDESTRIAN operation, motor B is not activated.
A START order interrupts the PEDESTRIAN operation and also starts motor B. During a standard working cycle, the PEDESTRIAN order
behaves exactly like a START order.
f2
At the end of the closing process, after having performed any slowing down phase, motor A pushes on the stop at maximum force for
conds. This function can be useful when using the electric lock, when closing is difficult. During this operation, the obstacle sensor is disabled
f3
PRE-BLINKING TIME
Before starting an opening or closing operation, the gate waits for
f4
F5
By enabling parameter
and the obstacle sensor is disabled. This function can be useful to help release the electric lock.
f5
STEP-BY-STEP MODE
F5
y
Enabling parameter
=
ment. A subsequent START order will start the movement in the opposite direction to the one that was interrupted.
For example: if the gate is opening, a START order stops the opening. The subsequent START order starts the closing phase of the gate.
f6
MULTIPLE RESIDENTS MODE
F6
Y
Enabling parameter
=
operation. During the closing phase, the START orders reverse the movement (from CLOSING
has higher priority than STEP-BY-STEP mode. By setting
n
automatically disabled (
).

STANDARD MODE

If both STEP-BY-STEP and COMMUNITY modes are disabled (
ring opening, the START orders stop the movement of the gate. During closing, the START orders reverse the movement.
GENERAL FUNCTIONS
% = percentage parameter
Times are expressed in seconds
10 sec
7 sec
0,0 sec
1,0 sec
n (y/n)
n (y/n)
n (y/n)
n (y/n)
F0
seconds. At the end of this time, the gate begins to close. To disable the AUTOMATIC
KICK BACK
KICK BACK
y
=
before opening, motor A closes for 0.5 seconds. During this time the force of the motor is at its maximum
activates the STEP-BY-STEP mode: during the opening and closing phase, the START orders stop the move-
activates the MULTIPLE RESIDENTS mode: during the OPENING phase, the START orders do not block the
USER MANUAL - 230 VAC MULTIFUNCTION CONTROL UNIT - 051D
n = disabled
PHOTOCELLS LOGIC: SLIDING
f8
ELECTRIC LOCK - FLASHING LIGHT 12VDC
l0
MOTOR HEATING/OIL RECYCLING
l1
ONLY MOTOR A MODE
l3
RESTORING MANOEUVRE WITH DEAD MAN FUNCTION
l4
WORKING CYCLES LIMIT - MAINTENANCE REQUEST
l5
TOTAL WORKING CYCLES COUNTER
l6
MINIMUM:
0. 0
st
0. 0
MINIMUM:
F1
represents the working time of motor A. The slowdown will not be perfor-
MINIMUM:
0. 0
MINIMUM:
0. 0
F3
seconds.
MINIMUM:
MINIMUM:
F5
n
=
F6
y
=
it will no longer be possible to change the value of
MINIMUM:
00
F5
n
F6
n
=
,
=
) the operating logic of the control unit is STANDARD: du-
19
xxx = see full description
01
= 10%
sec
MAXIMUM:
. If automatic closing is disabled, the gate remains
sec
MAXIMUM:
sec
MAXIMUM:
sec
MAXIMUM:
n
MAXIMUM:
n
MAXIMUM:
(→)
OPENING). Multiple residents mode
= 0%
MAXIMUM:
F
and L.
n (y/n)
0
0 min
n (y/n)
n (y/n)
n
xx
99
sec
a1
sec
2. 5
sec
F2
se-
5. 0
sec
y
y
F6
n
=
F5
which will be
n
= disabled

Advertisement

Table of Contents
loading

Related Products for Abexo 051D