When you are not navigating through the menu, the display shows the operating function. If multiple functions are active, the
one with the higher priority is shown. For example, input 9 on the terminal block is associated with the function programmed on
parameter e1. The value
e1
open contact; when the contact is closed, the control unit display shows go, i.e. it indicates that an event has been generated that
activates the START function. If shortly afterwards, a remote control button is pressed which has been stored with the function
r2
STOP. The control unit display shows
The following table lists all the operational functions that the control unit is able to manage, starting with the highest priority
and ending with the lowest.
DISPLAY
NAME
po
DEAD MAN OPENING
pc
DEAD MAN CLOSING
ST
STOP
OPENING
PHOTOCELL+
f5
CLOSING PHOTOCELL
CLOSING PHOTOCELL
tc
MODE 1
CLOSING PHOTOCELL
td
MODE 2
ta
OPENING PHOTOCELL
LIMIT SWITCH ERROR
1H
MOTOR A and MOTOR
B
LIMIT SWITCH ERROR
ea
MOTOR A
LIMIT SWITCH ERROR
eb
MOTOR A B
go
START
OPERATIONAL REPORTS AND PRIORITIES
in the initial configuration is
st
STOP, because the STOP function has a higher priority than the STOP function.
DESCRIPTION
When the DEAD MAN OPENING function is active, the gate is open
even if the STOP and PHOTOCELLS functions are active. When the
DEAD MAN OPENING function is no longer engaged, the gate
stops.
When the DEAD MAN CLOSING function is active, the gate is
closed even if the STOP and PHOTOCELLS functions are active.
When the DEAD MAN CLOSING function is no longer engaged,
the gate stops.
The STOP function is active. If the gate is moving, it will come to a
stop.
The OPENING PHOTOCELL and CLOSING PHOTOCELL MODE 1
functions are active at the same time.
The CLOSING PHOTOCELL MODE 1 function reverses the move-
ment during the closing phase and it has no effect during the
opening phase. If the CLOSING PHOTOCELL MODE 1 function is
active and the gate is stopped, it will NOT be started in OPEN when
a START order is received.
The CLOSING PHOTOCELL MODE 2 function reverses the move-
ment during the closing phase and it has no effect during the
opening phase. If the CLOSING PHOTOCELL MODE 2 function is
active and the gate is stopped, it will be started in OPEN when a
START order is received.
The OPENING PHOTOCELL function reverses the movement dur-
ing the closing phase suspends opening during the opening phase.
The OPENING LIMIT SWITCH and CLOSING LIMIT SWITCH func-
tions of motor A and motor B are active simultaneously. Motor
A and motor B will not be able to move when both opening or
closing.
The OPENING LIMIT SWITCH and CLOSING LIMIT SWITCH func-
tions of motor A are active simultaneously. Motor A will not be
able to move when both opening or closing.
The OPENING LIMIT SWITCH and CLOSING LIMIT SWITCH func-
tions of motor B are active simultaneously. Motor B will not be
able to move when both opening or closing.
The START function can open and close the gate. Its operation
also depends on the programming of the parameters made (
F6
step-by-step mode /
=multiple residents mode - see "GENER-
AL FUNCTIONS") and on the status of the other inputs.
USER MANUAL - 230 VAC MULTIFUNCTION CONTROL UNIT - 051D
e1
go
START. The START function is associated with a normally
=
14
CONTROL SOURCE
TERMINAL BLOCK
e1
e2
9
10
e1
e2
9
10
e3
11
e4
e5
12
13
e4
e5
12
13
e4
12
e5
13
e6
e7
22
23
e8
e9
24
25
e6
e7
22
23
e8
e9
24
25
F5
e1
e2
=
9
10
REMOTE CONTROL
r6
r7
r6
r7
r2
r1
r4