Install Electrical Panel

1. Perform HFR shutdown procedure. See HFRL oper-
ation manual for detailed instructions.
2. Disconnect the power supply to the machine.
3. Turn the disconnect switch on the rear base cover of
the machine to the "OFF" position
4. Remove the cover to allow access into the base
cube.
5. Install the pre-assembled panel on the left side of
the cube, directly opposite of the main control panel.
Note the locations of the 3 studs; One in each top
corner, and one in the bottom center.
a. Orient the panel so the mounting holes match
the stud locations of the cube.
b. Insert the panel into the base cube.
c. Orient the top of the panel such that the studs in
the cube wall extend through the holes in the
top corners of the panel.
d. Fasten the panel to the studs with the (3)
flanged hex nuts provided. Tighten the nuts.
6. Connect the cable (labeled 121002) extending from
the panel to the yellow cable splitter located on the
lower left side of the main machine control panel.
a. Remove the two screws to free the splitter from
the panel.
b. Insert the cable end into the open port on the
splitter and tighten. Note that the plug is keyed
and only fits in the splitter in one orientation.
c. Reattach the splitter to the panel.
7. If there is no available connection on the splitter, an
alternate CAN connection will need to be used. The
alternate location may require a different gendered
cord (122487 is provided for this purpose). Consult
the system manual in finding an alternate connec-
tion location.
10
8. Remove one of the hole plugs located on the top of
the base cube directly over the disconnect panel
that was just removed.
NOTE: There are three holes on the top edge of the
base cube. The plug can be easily pushed out from
inside the cube.
9. Replace the removed plug with the provided plastic
edge bushing
a. The bushing will snap into place by aligning the
smaller diameter end of the bushing on top of
the hole and pressing the bushing down through
the hole from outside the cube.
10. Insert the male ends of the sensor cords labeled
FCM1A and FCM2B through the bushing and into
the base cube.
11. Connect the cord labeled FCM1A to port "1" (Refer
to F
. 2, page 5) on the FCM labeled FCM1.
IG
12. Connect the cord labeled FCM2B to port "1" (Refer
to F
. 2, page 5) on the FCM labeled FCM2.
IG
13. Attached the wire anchor to the inside face of the
base by inserting the provided screw through the
anchor and the weld nut indicated in F
in place by tightening the hex nut on the screw from
the outside of the base.
14. Secure the cords to the panel and the base cube by
using wire ties (not provided) and the installed plas-
tic anchors.
. 6. Secure