Set the ADM to Recognize which
Level Sensors are to Operate
NOTE: Two sensors must be selected for each material
with a level sensor, regardless if there is only one low
level sensor installed.
1. Remain within the ADM Refill Screen.
2. For the appropriate chemical side, select and check
the middle sensor.
3. For the appropriate chemical side, select and check
the bottom sensor.
4. Press
.
Set the Level Sensors Output
Function
1. Navigate to the ADM Advanced Screen 4.
2. Press
.
3A2806A
3. If it is desired to stop dispensing when a low level is
sensed, select and check "Low Material Disables
Dispense".
NOTE: Setting this option initiates a deviation condition
and disables the machine from operation when there is
a low level condition. When a low level is sensed, the
machine will not cycle until the sensor see material. A
pop-up screen on the ADM alerts the operator of the
specific level condition.
4. If it is not desired to stop dispense, verify Low Mate-
rial Disables Dispense" is unchecked.
NOTE: This option is the default setting of the system
and is set as a deviation condition. When a deviation is
issued, the machine will continue to cycle and will not be
affected by the deviation.
NOTE: A low level condition generates a pop-up mes-
sage on the ADM that can only be cleared by the opera-
tor. If the "Low Material Disables Dispense" option is
selected, dispensing can resume with a remote start
signal when material is replenished and the sensor sees
material. It is not necessary to clear the ADM to initiate a
start unless the ADM is used as the start device.
5. Press
.
Setup
15