Description - Atlas Copco XAS 185 CDU T4 Original Instructions Manual

Table of Contents

Advertisement

LEGEND
F1
Circuit Breaker
G1
Alternator
G2
Battery
H1
Temperature Alarm Lamp
H2
General Alarm lamp
HTR
Air inlet preheat
K0
Starter solenoid (part of M1)
K1
Relay
K2
Relay
K3
Relay
K4
Relay
K5
Relay
M1
Starter Motor
P1
Hour meter
P2
Fuel level gauge
S1
Contact switch (Off-on-overide-start)
S2
Temperature switch Engine
S3
Oil Pressure switch Engine
S4
Lamp test switch
S5
Temperature switch (Compressor)
S6
Low fuel level switch
S7
Fuel level sender
S8
Preheat Pushbutton
Y1
Fuel Solenoid Valve
R1
Resistor
V2
Diode

DESCRIPTION

Operation of the electric circuit In detail
Start button S1 position 1:
Line 2 on 12V contact K3 closed (30-87), lamp H2 is
on. K4 excites contact K4 (87-87a). Thermocontact
element S5 normally closed, K1 excites contact K1
(30-87).
Use of preheat:
Start button S1 position 1 press pushbutton S8,
energizes relay K5 and provides power to the glow
plug.
Start button S1 position 2:
Line 3 on 12V (override function) hour meter P1,
and fuel solenoid Y1 is excited. Thermocontact
engine S2 normally closed, oil pressure contact S3
open.
Start button S1 position 3:
Start relay K0 is excited and starter motor is running,
engine builds up oil pressure and oil pressure
contact S3 closes. K3 excited and contact K3
changes over to (30-87). Relay K2 no longer
excited, contact K2 opens, lamp H1 goes out.
Alternator also commences supplying voltage and
K4 is no longer excited and contact K4 changes over
to (87-87a). Lamp H2 goes out, one can release
start button S1 and it returns to position 1. Exciting
the safety devices occurs no longer across line 3 but
across line 2 to line 4 and this way to line 3.
Explanation of shutdowns:
Oil pressure contact S3 opens, K3 no longer
excited. K3 changes over (87a-87), engine cuts out
because fuel solenoid Y1 no longer excited and
lamp H2 goes on simultaneously.
Thermocontact S2 opens, K3 no longer excited. K3
changes over (87a-87), engine cuts out because
fuel solenoid Y1 no longer excited and lamp H2
goes on simultaneously.
Thermocontact S5 opens, K1 no longer excited.
- 21 -
Contact K1 changes over (87-87a). K3 no longer
excited. K3 changes over (97a-87), engine cuts out
because fuel solenoid Y1 no longer excited and
lamp H2 and H1 go on simultaneously. Take-over
relay K2 is excited simultaneously with H1 and
contact K2 closes (30- 87).
Thermocontact S5 cools off and closes, K1 excited
again and contact K1 changes over (87-87a).
However, lamp H1 remains on across line 9 and
contact K2 (30-87).
A fault in the alternator part causes terminal D+ to
go to 0V and K4 to be excited. Contact K4 changes
over to (87a-87), engine cuts out because fuel
solenoid Y1 no longer excited and lamp H2 goes on
simultaneously.