RSP3 installation and user's guide
www.renishaw.com
RSP3 cranked stylus carrying capability for
typical stylus combinations
Each RSP3 probe has been optimised for maximum flexibility and sensor performance over a specific stylus range and with different crank
carrying capabilities in mind.
Please refer to Renishaw's stylus catalogue for full details of cranked and star stylus configurations that are available. It is recommended that
a 'one piece' star stylus is used wherever possible to help minimise mass. However, greater flexibility is possible by configuring a star centre
together with one or more cranked styli. Users must be sure that the overall mass of the star centre together with its multiple cranked styli
does not exceeded the recommendations found in the table below.
Straight 'down' styli can be added to RSH3-1 / 2 / 3 / 4 stylus holders below the crank centre to continue the projection 'down' from the
stylus holder, providing that the maximum overall stylus length and mass for that stylus holder is not exceeded.