JLG E600J Operation And Safety Manual page 85

Table of Contents

Advertisement

TELESCOPING IN AND LOWERING THE BOOM
1. Install the spool plug in the location shown and push the
control lever on the valve up.
2. Install the handle into the hand pump and pump the handle
until the desired platform position is reached.
3. Push the control lever down when complete. Remove the
handle from the hand pump and the spool plug from the
valve.
3121710
SECTION 5 - EMERGENCY PROCEDURES
LOWERING THE BOOM
1. Push the control lever on the valve up.
2. Install the handle into the hand pump and pump the handle
until the desired platform position is reached.
3. Push the control lever down when complete. Remove the
handle from the hand pump.