Power
Internal battery
External battery
Environmental
specifications
Reflectors
64
Type
External supply voltage
Type
Battery
GEB222
Li-Ion
Type
Battery
GEB371
Li-Ion
Temperature
Type
All instruments
Leica SD cards
Battery internal
Protection against water, dust and sand
Type
All instruments
Humidity
Type
All instruments
Type
Additive
Constant [mm]
Standard prism,
0.0
GPR1
Mini prism,
+17.5
GMP101
360° prism,
+23.1
GRZ4 / GRZ122
360° mini prism,
+30.0
GRZ101
Reflector tape
+34.4
S, M, L
Reflectorless
+34.4
There are no special prisms required for ATR or for AutoSearch.
Description
Nominal voltage 12.8 V DC, Range
11.5 V-13.5 V
Nominal
Voltage
7.4 V ⎓
Voltage
13 V
Operating temperature
[°C]
−20 to +50
−40 to +80
−20 to +55
Protection
IP55 (IEC 60529)
Protection
Max 95% non condensing
The effects of condensation are to be effectively
counteracted by periodically drying out the instru-
ment.
ATR
yes
yes
yes
yes
yes
no
Capacity
6.0 Ah
Capacity
16.8 Ah
Storage temperature
[°C]
−40 to +70
−40 to +80
−40 to +70
AutoSearch
yes
yes
yes
not
recommended
no
no
Technical Data