Technical Data; Angle Measurement; Distance Measurement With Reflectors; Distance Measurement Without Reflectors - Leica Geosystems iCON iCT30 User Manual

Construction layout tool
Table of Contents

Advertisement

7
7.1
Accuracy
Characteristics
7.2
Range
Accuracy
Characteristics
7.3
Range

Technical Data

Technical Data

Angle Measurement

Available angular accuracies
["]
9
Absolute, continuous, diametric.

Distance Measurement with Reflectors

Shortest measuring distance:
Maximum measuring distance:
Measurements can be made to reflector tapes over the entire range without
external ancillary optics.
Accuracy refers to measurements to standard prisms.
Distance
Standard
measuring
deviation
mode
ISO 17123-4,
standard prism
Single Auto
1 mm
Continuous
3 mm
with lock
Beam interruptions, severe heat shimmer and moving objects within the beam
path can result in deviations of the specified accuracy.
Type
Principle
Type
Carrier wave
Measuring system

Distance Measurement without Reflectors

R80
Kodak Gray Card
White side, 90 % reflective
Grey side, 18 % reflective
Range of Measurement:
Standard deviation
Hz, V
ISO 17123-3
[mgon]
2.8
1.5 m
80 m
Standard
deviation
ISO 17123-4,
tape
3 mm
3 mm
Description
Phase measurement
Coaxial, visible red laser
658 nm
System Analyzer Basis 100–150 MHz
Range
[m]
80
80
1.5 m to 80 m
Measurement
time, typical [s]
2.4
< 0.15
[ft]
260
260
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icon icb50Icon icb70

Table of Contents