Advertisement

Quick Links

20
30
40
50
Field Manual / HƯ NG D N S D NG
English /Ti ng Vi t
Version 1.0
DNA03/ DNA10
Edited with the trial version of
Foxit Advanced PDF Editor
To remove this notice, visit:
www.foxitsoftware.com/shopping

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DNA03 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Leica Geosystems DNA03 Series

  • Page 1 Edited with the trial version of Foxit Advanced PDF Editor To remove this notice, visit: www.foxitsoftware.com/shopping DNA03/ DNA10 Field Manual / HƯ NG D N S D NG English /Ti ng Vi t Version 1.0...
  • Page 2 Digital Levels DNA03/ DNA10 Functions and Programs To use the equipment in the permitted manner, please refer to the detailed safety instructions in the User Manual. © 2002 Leica Geosystems AG Heerbrugg, ® All rights reserved.
  • Page 3: Table Of Contents

    Contents DNA03/ DNA10 Series ......4 Change from Intermediate or Stake Out..........19 Batteries ............. 4 PCMCIA-card ..........5 Intermediate sight .......... 19 Keyboard............ 6 <Pt-Pt> (Point to Point) ........20 Set out ............20 Fixed keys ............6 Level test ..........22 Key combinations..........
  • Page 4: Dna03/ Dna10 Series

    Edited with the trial version of Foxit Advanced PDF Editor To remove this notice, visit: www.foxitsoftware.com/shopping DNA03/ DNA10 Series Removing the batteries / Tháo pin ra Batteries/ Pin Inserting the batteries / G n pin vào máy DNA_BTTR_2 Place one of your hands below the open batttery compartment to catch the battery and with the other hand, pull the lever towards the display.
  • Page 5: Pcmcia-Card

    Edited with the trial version of Foxit Advanced PDF Editor Removing the card / L y th nh ra kh i máy To remove this notice, visit: PCMCIA-card/ Th ghi s li u PCMCIA www.foxitsoftware.com/shopping Card compartment cover / N p đ y h p th Open /M : Press latch.
  • Page 6: Keyboard

    Edited with the trial version of Foxit Advanced PDF Editor To remove this notice, visit: Fixed keys Keyboard/ Bàn phím www.foxitsoftware.com/shopping Switching intermediate sight. / Chuy n sang ch đ đo đi m trung gian. Set measurement mode. /Cài đ t ch đ đo. Key with any function from the FNC-menu.
  • Page 7: Key Combinations

    Edited with the trial version of Key combinations /Các phím k t h p Foxit Advanced PDF Editor PgUp To remove this notice, visit: SET OUT /B trí đi m thi t k ra hi n trư ng www.foxitsoftware.com/shopping Phím SHIFT + Phím = Page Up Phím SHIFT + Phím INT = SETOUT "Page Up"= scroll up to previous "page"...
  • Page 8: Navigation Keys

    Edited with the trial version of Foxit Advanced PDF Editor Navigation keys /Các phím di chuy n Entry keys /Các phím nh p s li u To remove this notice, visit: www.foxitsoftware.com/shopping Enter numbers, letters and special characters. / Nh p s ch và các The navigation keys take on different functions, ký...
  • Page 9: Display

    Edited with the trial version of Foxit Advanced PDF Editor Signals field of selection out of a list. / ! " To remove this notice, visit: Ký hi u ch n Display / Màn hình www.foxitsoftware.com/shopping trong 1 danh sách. Navigates the list / Phím di chuy n tròn daanh sách.
  • Page 10: Menü

    Edited with the trial version of Foxit Advanced PDF Editor To remove this notice, visit: Menu www.foxitsoftware.com/shopping Phím SHIFT + Phím PROG = MENU Calling up the Menu Ch nh sáng t i màn hình Đ cong qu đ t Cài đ...
  • Page 11 Edited with the trial version of Foxit Advanced PDF Editor To remove this notice, visit: www.foxitsoftware.com/shopping Thông s truy n Data Kho ng cách Đơn v Nhi t đ Ngày Ngày/ Gi Gi (24h) S Job còn tr ng Thông tin h th ng Phím USER Nhi t đ...
  • Page 12: Data

    Edited with the trial version of Foxit Advanced PDF Editor To remove this notice, visit: Data / S li u www.foxitsoftware.com/shopping Calling up the Data-Manager / M ra m c qu n lý s li u Qu n lý s li u xem và...
  • Page 13 Edited with the trial version of Foxit Advanced PDF Editor To remove this notice, visit: www.foxitsoftware.com/shopping Xu t s li u Sang PC card (Job đi m đo/t a đ Ra c ng Serial (Job đi m đo/t a đ Nh p s li u vào DNA03 (t th ghi) Đi m t a đ...
  • Page 14: Prog

    Edited with the trial version of Foxit Advanced PDF Editor To remove this notice, visit: Prog / Chương trình www.foxitsoftware.com/shopping Calling up the measuring program / G i ra các chương trình đo Các chương trình Ch đo Không lưu Có...
  • Page 15 Edited with the trial version of Foxit Advanced PDF Editor To remove this notice, visit: www.foxitsoftware.com/shopping Đư ng đo th y chu n Ch n Job Phương pháp : Ch n đư ng Ch n đúng sai Ki m tra và hi u ch nh máy Ch n Job Ch n phương pháp...
  • Page 16: Mode

    Edited with the trial version of Foxit Advanced PDF Editor To remove this notice, visit: Mode www.foxitsoftware.com/shopping Calling up the measuring mode / G i ra các ch đ đo Ch đ đo Đo đơn Trung bình S l n đo t 2 - 99 Trung bình S l n đo min = 2 - 99 S l n đo max = 2 - 99...
  • Page 17: Measure & Record

    Edited with the trial version of Foxit Advanced PDF Editor To remove this notice, visit: Measure & Record / Đo và lưu www.foxitsoftware.com/shopping After switching on the instrument the basic program Back, Dist and HCol are displayed with their "Measure & Record" always is ready to take mea- respective values.
  • Page 18: Foresight Display

    Edited with the trial version of Foxit Advanced PDF Editor Foresight display /Màn hình mia trư c To remove this notice, visit: www.foxitsoftware.com/shopping Enter all required values (PtID, H0, poss. Rem) and trigger measurement with measurement key. / Nh p t t c các giá tr yêu c u (PtID, H0, Rem) và đo b ng phím đo c a máy DNA03.
  • Page 19: Change From Intermediate Or Stake Out

    Edited with the trial version of Foxit Advanced PDF Editor To remove this notice, visit: www.foxitsoftware.com/shopping Change from Intermediate or Stake Out Chuy n sang đo đi m trung gian hay b trí cao đ Intermediate sight / Đo ng m đi m trung gian The PtIDs are incremented after each measurement.
  • Page 20: Pt> (Point To Point)

    Edited with the trial version of Foxit Advanced PDF Editor <Pt-Pt> (Point to Point) / B m vào đo đi m - To remove this notice, visit: Set out/ B trí cao đ ra hi n trư ng đi m www.foxitsoftware.com/shopping Trigger measurement with measuring [SET OUT] Starts set out display:/ B m phím...
  • Page 21 Edited with the trial version of Foxit Advanced PDF Editor <CONT> O ut / i n To remove this notice, visit: www.foxitsoftware.com/shopping Continue to measuring display set out. / Amount to O ut / in : Giá tr ra/ vào Out (+) = move staff further away / Out (+) = Di B m CONT đ...
  • Page 22: Level Test

    Conditions on the distances: Level test 1. Station The center has to be within an accu racy of +/-1 m "A x Bx" method 2. Station b _ 2.5 m Two varieties can be mesured with this method: From the center procedure: min.
  • Page 23 Kukkamäki procedure: Instrument positioned in the center of the staffs and on the outside of staff B at a distance b (b = a). a = approx. 20 m. Distance conditions as before.. DNA03_Nivellierprobe_2 1. Position 2. Position Staff A Staff B...
  • Page 24: A X X B" Method

    "A x x B" method Features of this method: The distances have a 1:2 ratio in every position. Förstner procedure: Instrument positioned at each third beteen the staffs. Staff distance D approx. 45 m - 60 m. Distance conditions: 1. Station: 0.2 x D < Dist_A1 < 0.4 x D 2.
  • Page 25 Näbauer procedure: Instrument position outside of the staffs. a = approx. 15 m - 20 m. Distance condition: same as above. DNA03_Nivellierprobe_5 1. Position 2. Position Staff A Staff B...
  • Page 26: Sensor-Error Messages

    Sensor-error messages List of the "Measurement not possible" messages: Error message Counter measure Picture too dark. Light up staff. Picture too bright Darken staff or reduce lighting to staff. No staff present or staff hidden or insufficient code Check targeting. length.
  • Page 27 Our commitment to total customer being equipped with a quality satisfaction system which meets the International Standards of Quality Ask your local Leica Geosystems Management and Quality Systems agent for more information about our (ISO standard 9001) and TQM program.

This manual is also suitable for:

Dna10 series

Table of Contents